MPCBL0010 SBC—Operating the Unit
Intel NetStructure® MPCBL0010 Single Board Computer
Technical Product Specification October 2006
30 Order Number: 304120
3.4.1 Chassis Installation
1. Insert the MPCBL0010 SBC into the chassis with the latching cams at a 75º angle.
This will set the latching cams into the installation position. Move the latching cam
by pressing the handle inward to free the latching cam for rotation.
2. While holding inward pressure on the handle, slide the MPCBL0010 SBC into the
chassis. Begin rotating the latching cam back to 0º allowing the cam to assist with
insertion. As the SBC is inserted, the AdvancedTCA backplane connectors are
mated to the SBC. If necessary, use your thumbs to apply pressure to the SBC
faceplate near the handles to make sure the SBC is fully inserted.
Caution: Do not apply pressure to the AdvancedMC faceplate, as this could damage the
connectors at the rear of the AdvancedMC module.
3. Once the SBC is installed, rotate the handles into the vertical position.
3.4.2 Chassis Extraction
The AdvancedTCA Hot Swap switch is activated by pushing in the lower handle (or the
left handle when the SBC is mounted in the horizontal position). When the handle is
pushed inward, a small metal slider will activate the Hot Swap switch.
Note: The ratcheting function of the handle allows the handle to be moved without affecting
the position of the latching cam that holds the SBC in the chassis (see illustration in