Hardware Management
The MPCBL0010 SBC also has a second "dead time" (45 seconds) used to avoid PCI - Express hot plug signaling during the operating system load. This delay is applied from the time the SBC goes to M4 state. There is no hot plug "attention button" during that delay. The IPMC asserts the "attention button" only after the delay to notify the operating system that a new device is ready to power.
10.10.1Pre-Defined Resources for AdvancedMC Modules
In order to support AdvancedMC hot add, the SBC has to reserve resources that are not being used by a device when the SBC is booted. It is not possible for the SBC to know exactly what resources an AdvancedMC module that is
For each AdvancedMC module slot, the following resources are reserved:
•8 PCI buses
•IO: 8K
•Memory: 4000000h ;(64MB)
•
10.11Temperature and Voltage Sensors
Temperature and voltage sensors are monitored by the MPCBL0010 SBC. These sensors are used to ensure that the MPCBL0010 SBC is operating at its
•Lower
•Lower Critical
•Upper
•Upper Critical
If the lower critical or upper critical threshold is exceeded, it raises a major alarm. If the lower
Only critical thresholds which are exceeded turn on the solid red LED. However, for any events above, the IPMC forwards the events to the AdvancedTCA shelf manager to log into the SEL.
Table 123 lists the sensor numbers, normal values, and thresholds for all voltage and temperature sensors.
| Intel NetStructure® MPCBL0010 Single Board Computer |
October 2006 | Technical Product Specification |
Order Number: 304120 | 137 |