
| 
 | 
 | 
 | 
 | 
 | 
 | MPCBL0010— | 
| 
 | 
 | 
 | 10.8.2 | Board Device Channel Port Selection Identifiers | 131 | |
| 
 | 
 | 
 | 
 | 10.8.2.1 | SetBoardDeviceChannelPortSelection | 132 | 
| 
 | 
 | 
 | 
 | 10.8.2.2 | GetBoardDeviceChannelPortSelection | 133 | 
| 
 | 
 | 
 | 
 | 10.8.2.3 | GetBoardDevicePossibleSelection | 133 | 
| 
 | 
 | 
 | 10.8.3 | Set Control State | 134 | |
| 
 | 
 | 
 | 10.8.4 | Get Control State | 134 | |
| 
 | 
 | 
 | 10.8.5 | Controls Identifier Table | 134 | |
| 10.9 | Hot Swap Process | 135 | ||||
| 
 | 
 | 
 | 10.9.1 | Hot Swap LED | 136 | |
| 10.10 | AdvancedMC Module Activation | 136 | ||||
| 
 | 
 | 
 | 137 | |||
| 10.11 | Temperature and Voltage Sensors | 137 | ||||
| 
 | 
 | 
 | 10.11.1Processor Events | 139 | ||
| 
 | 
 | 
 | 10.11.2DIMM Memory Events | 139 | ||
| 
 | 
 | 
 | 10.11.3System Firmware Progress (POST Error) | 139 | ||
| 
 | 
 | 
 | 10.11.4Critical Interrupts | 139 | ||
| 
 | 
 | 
 | 10.11.5System ACPI Power State | 139 | ||
| 
 | 
 | 
 | 10.11.6IPMB Link Sensor | 140 | ||
| 
 | 
 | 
 | 10.11.7FRU Hot Swap | 140 | ||
| 10.12 | Reset | 
 | 140 | |||
| 
 | 
 | 
 | 10.12.1Warm Reset | 141 | ||
| 
 | 
 | 
 | 10.12.2Hard Reset | 141 | ||
| 10.13 | Field Replaceable Unit (FRU) Information | 141 | ||||
| 10.14 | IPMC Firmware Code | 142 | ||||
| 11.0 Serial Over LAN (SOL) | 145 | |||||
| 11.1 | References | 145 | ||||
| 11.2 | SOL Architecture | 145 | ||||
| 
 | 
 | 
 | 11.2.1 | SOL Implementation | 145 | |
| 
 | 
 | 
 | 11.2.2 | Architectural Components | 147 | |
| 
 | 
 | 
 | 
 | 11.2.2.1 IPMC | 147 | |
| 
 | 
 | 
 | 
 | 11.2.2.2 | Ethernet Controller | 147 | 
| 11.3 | Theory of Operation | 147 | ||||
| 
 | 
 | 
 | 11.3.1 | Front Panel Serial Port or Rear Transition Module | 147 | |
| 
 | 
 | 
 | 11.3.2 | Serial Over LAN | 147 | |
| 11.4 | Serial Over LAN Client | 148 | ||||
| 11.5 | Reference Configuration Script | 148 | ||||
| 11.6 | Supported Usage Model | 149 | ||||
| 
 | 
 | 
 | 11.6.1 | Configuring the Blade for SOL | 149 | |
| 11.7 | Reference Script (reference_cfg) | 150 | ||||
| 
 | 
 | 
 | 11.7.1 | SOL Configuration Reference Script (reference_cfg) | 150 | |
| 
 | 
 | 
 | 11.7.2 | Default Behavior | 150 | |
| 
 | 
 | 
 | 11.7.3 | SOL User Information | 150 | |
| 
 | 
 | 
 | 11.7.4 | LAN Parameters | 150 | |
| 
 | 
 | 
 | 11.7.5 | SOL Parameters | 151 | |
| 
 | 
 | 
 | 11.7.6 | Channel Parameters | 151 | |
| 
 | 
 | 
 | 11.7.7 | Command Line Options | 151 | |
| 11.8 | Setting up a Serial Over LAN Session | 152 | ||||
| 
 | 
 | 
 | 11.8.1 | Target Blade Setup | 152 | |
| 
 | 
 | 
 | 
 | 11.8.1.1 | BIOS Configuration | 152 | 
| 
 | 
 | 
 | 
 | 11.8.1.2 | Operating System Configuration | 153 | 
| 
 | 
 | 
 | 
 | 11.8.1.3 | sbcutils RPM Installation | 155 | 
| 
 | 
 | 
 | 
 | 11.8.1.4 | Execute the reference_cfg Script | 155 | 
| 
 | 
 | 
 | 11.8.2 | Client Blade Setup | 157 | |
| 
 | 
 | 
 | 
 | 11.8.2.1 | Configure the Ethernet Port | 157 | 
| 
 | 
 | 
 | 
 | 11.8.2.2 | Installing ipmitool | 158 | 
| Intel NetStructure® MPCBL0010 Single Board Computer | 
 | |||||
| Technical Product Specification | 
 | October 2006 | ||||
| 6 | 
 | 
 | 
 | 
 | 
 | Order Number: 304120 | 
