MPCBL0010
Table 128. Switchover Mode Values
Name | Description | Value |
|
|
|
PLL_HOLDOVER | Use PLL holdover detection | 0x40 |
|
|
|
LOST_CLOCK | Use loss of clock signal | 0x00 |
|
|
|
12.4.6Select Reference Clock
To select the received reference clock from AdvancedMC for AdvancedTCA backplane CLK3B and CLK3A, use the following:
Functions:
IOCTL_SELECT_RECEIVED_REF_CLK3A
IOCTL_SELECT_RECEIVED_REF_CLK3B
Table 129. Received Reference Clock Values
Name | Description | Value |
|
|
|
AMC_B1 | Source from AdvancedMC B1 | 0x00 |
|
|
|
AMC_B2 | Source from AdvancedMC B2 | 0x10 |
|
|
|
12.4.7Reference Frequency for PLL
To select the reference frequency that feeds the clocks to the PLL, use the following:
Function:
IOCTL_SELECT_REF_FREQUENCY
Table 130. Reference Frequency PLL Values
Name | Description | Value | |
|
|
| |
REF_CLK1_8kHz | PLL input clocks = CLK1A and CLK1B | 0x00 | |
(8 kHz, per AdvancedTCA specification) | |||
|
| ||
|
|
| |
REF_CLK2_19_44MHz | PLL input clocks = CLK2A and CLK2B | 0x02 | |
(19.44 MHz, per AdvancedTCA specification) | |||
|
| ||
|
|
|
12.4.8Primary/Secondary Redundant Clock
To select the primary or secondary redundant clock, use the following:
Function:
IOCTL_SELECT_REDUNDANT_CLOCK
Table 131. Primary/Secondary Redundant Clock Values
Name | Value |
|
|
PRIMARY_CLOCK | 0x00 |
|
|
SECONDARY_CLOCK | 0x01 |
|
|
Intel NetStructure® MPCBL0010 Single Board Computer |
|
Technical Product Specification | October 2006 |
166 | Order Number: 304120 |