Table 31. POST Codes Generated by the BMC and Logged at the Seven

Segment LED

 

Code

Descriptions

Classification

Operation to

 

Recover

 

 

 

 

 

 

 

 

 

 

5

 

3

CPU3 Configuration Error (Disabled)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

4

CPU3 Configuration Error (Illegal Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

5

CPU3 Configuration Error (Different Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

6

CPU3 I2C Access Error (PIROM)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

7

CPU3 I2C Access Error (Temperature Monitor)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

8

MB Power Failure (Main 5.0V)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

9

MB Power Failure (Main 3.3V)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

A

MB Power Failure (Main 2.5V)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

B

MB Power Failure (Main 1.8V)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

C

MB Power Failure (Main 1.5V)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

D

MB Power Failure (Main 1.2V0)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

E

MB Power Failure (Main 1.2V1)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

F

MB Power Failure (Main 1.2V2)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

0

MB Power Failure (Voltage Type Unknown)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

1

MVR0 Power Failure

Error, error event

SEL List

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

2

MVR1 Power Failure

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

3

MVR2 Power Failure

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

4

MVR3 Power Failure

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

5

PS0 Configuration Error (Absent)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

6

PS0 Configuration Error (Illegal Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

7

PS0 Configuration Error (Insufficient

Error, error event

 

 

 

 

Resources)

logged to SEL

 

 

 

 

 

 

 

6

 

8

PS1 Configuration Error (Insufficient

Error, error event

 

 

 

 

Resources)

logged to SEL

 

 

 

 

 

 

 

6

 

9

PS1 Configuration Error (Different Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 