152 Intel® Server System SR9000MK4U Product Guide
3. Choose “Console Redirection”:
4. Choose “COM1 Console Redirection”:
5. Set the COM1 Speed to 9600/19200:
The baud rate must be equal to the speed specified for serial redirection functions of
the BIOS, and the speed used for the configuration of the boot loader and operating
system.
6. By default, a null user and null password is available from SOL.
7. The user name and user password are configurable with the SYSCFG utility. For
information about this utility, see the EFI Utility User’s Guide.
8. Bundled management software will use User #10. Do not use this user number if
you plan to use the management software that is included with your server system.
Server Management Menu
Examine and set server management parameters.
Console Redirection
Management LAN
SEL Clear
Exit
Console Redirection Menu
Examine and set console redirection parameters.
COM1 Console Redirection
Exit
COM1 Console Redirection Menu
Examine and set console redirection parameters.
Headless Support [Enable]
COM1 Speed [19200 bps]
Exit
Use Enter to change value.