Table 31. POST Codes Generated by the BMC and Logged at the Seven

Segment LED

 

Code

Descriptions

Classification

Operation to

 

Recover

 

 

 

 

 

 

 

 

 

 

 

3

 

A

reserved

 

 

 

 

 

 

 

 

3

 

B

reserved

 

 

 

 

 

 

 

 

3

 

C

Detailed log collection started by WDT overflow

Error

BMC Error

 

 

 

 

 

 

3

 

D

BMC restarted by WDT overflow

Error

 

 

 

 

 

 

 

3

 

E

Failed in task generation

Error

 

 

 

 

 

 

 

3

 

F

Illegal or mismatch format of GUID

Error

 

 

 

 

 

 

 

4

 

0

CPU0 Thermal Trip

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

1

CPU0 Configuration Error (Absent)

Error, error event

SEL List

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

2

CPU0 Configuration Error (Disabled)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

3

CPU0 Configuration Error (Illegal Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

4

CPU0 I2C Access Error (PIROM)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

5

CPU0 I2C Access Error (Temperature Monitor)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

6

CPU1 Thermal Trip

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

7

CPU1 Configuration Error (Disabled)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

8

CPU1 Configuration Error (Illegal Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

9

CPU1 Configuration Error (Different Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

A

CPU1 I2C Access Error (PIROM)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

B

CPU1 I2C Access Error (Temperature Monitor)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

C

CPU2 Thermal Trip

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

D

CPU2 Configuration Error (Disabled)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

E

CPU2 Configuration Error (Illegal Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

4

 

F

CPU2 Configuration Error (Different Type)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

0

CPU2 I2C Access Error (PIROM)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

1

CPU2 I2C Access Error (Temperature Monitor)

Error, error event

SEL List

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

5

 

2

CPU3 Thermal Trip

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

Intel® Server System SR9000MK4U Product Guide

173

Page 195
Image 195
Intel manual Intel Server System SR9000MK4U Product Guide 173