Intel® Server System SR9000MK4U Product Guide 173
3Areserved
3Breserved
3 C Detailed log collection started by WDT overflow Error BMC Error
3 D BMC restarted by WDT overflow Error
3 E Failed in task generation Error
3 F Illegal or mismatch format of GUID Error
4 0 CPU0 Thermal Trip Error, error event
logged to SEL
4 1 CPU0 Configuration Error (Absent) Error, error event
logged to SEL SEL List
4 2 CPU0 Configuration Error (Disabled) Error, error event
logged to SEL
4 3 CPU0 Configuration Error (Illegal Type) Error, error event
logged to SEL
4 4 CPU0 I2C Access Error (PIROM) Error, error event
logged to SEL
4 5 CPU0 I2C Access Error (Temperature Monitor) Error, error event
logged to SEL
4 6 CPU1 Thermal Trip Error, error event
logged to SEL
4 7 CPU1 Configuration Error (Disabled) Error, error event
logged to SEL
4 8 CPU1 Configuration Error (Illegal Type) Error, error event
logged to SEL
4 9 CPU1 Configuration Error (Different Type) Error, error event
logged to SEL
4 A CPU1 I2C Access Error (PIROM) Error, error event
logged to SEL
4 B CPU1 I2C Access Error (Temperature Monitor) Error, error event
logged to SEL
4 C CPU2 Thermal Trip Error, error event
logged to SEL
4 D CPU2 Configuration Error (Disabled) Error, error event
logged to SEL
4 E CPU2 Configuration Error (Illegal Type) Error, error event
logged to SEL
4 F CPU2 Configuration Error (Different Type) Error, error event
logged to SEL
5 0 CPU2 I2C Access Error (PIROM) Error, error event
logged to SEL
5 1 CPU2 I2C Access Error (Temperature Monitor) Error, error event
logged to SEL SEL List
5 2 CPU3 Thermal Trip Error, error event
logged to SEL
Table 31. POST Codes Generated by the BMC and Logged at the Seven
Segment LED
Code Descriptions Classification Operation to
Recover