Hot-swapping a Hard Drive

Note: Remove only the failed drive. Removing the wrong drive could cause the system to malfunction or may cause data loss.

1.Use the LED indicators at the top of the hard drive carriers to determine which drive has failed. The red LED indicates the failed hard drive. See letter “A” in the figure below.

A

AF001115

Figure 30. Hard Drive LED Indicators

2. Install the new hard drive. See “Installing a Hard Drive” on page 38.

Installing and Removing a Memory Box

Your system was shipped with two memory boxes installed and two memory box filler panels installed. Before you can use your server system, each memory box must be populated with either four or eight DIMMs.

Note: The system will not boot if a memory box is installed with no DIMMs in it.

You will need to remove the memory box to perform the following operations:

To replace a memory box

To install or remove DIMMs

To install or remove the mounting plate