Intel SR9000MK4U manual Installing and Removing DIMMs, Dimm Installation Guidelines

Models: SR9000MK4U

1 258
Download 258 pages 38.35 Kb
Page 70
Image 70

Installing and Removing DIMMs

DIMM Installation Guidelines

Each installed memory box must have either four or eight DIMMs installed, as shown below.

Four DIMM installation: Install DIMMs in JD0B1, JD0A1, JD2B1, JD2A1

Eight DIMM installation: DIMMs installed in each socket

Note: When facing the front or rear of the memory box, the four sockets at the left are positioned in the opposite direction from the four sockets at the right. Be sure to reverse the DIMMs accordingly. Make sure the notches at the center of the DIMMs line up correctly with the tabs in the center of the sockets.

AF001124

Figure 36. Four-DIMM Installation Pattern

AF001125

Figure 37. Eight-DIMM Installation Pattern

Note: The system will not boot if a memory box is installed with no DIMMs in it.

48

Intel® Server System SR9000MK4U Product Guide