Table 31. POST Codes Generated by the BMC and Logged at the Seven

Segment LED

 

Code

Descriptions

Classification

Operation to

 

Recover

 

 

 

 

 

 

 

 

 

 

 

6

 

A

PS0 Power Failure (Insufficient Resources)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

B

PS1 Power Failure (Insufficient Resources)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

C

CPU / MMR Overinstall (PS Insufficient

Error, error event

 

 

 

 

Resources)

logged to SEL

 

 

 

 

 

 

 

6

 

D

MB I2C Access Error (Sensor0)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

E

MB I2C Access Error (Sensor1)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

6

 

F

MB I2C Access Error (Voltage Margin0)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

0

MB I2C Access Error (Voltage Margin1)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

1

MB I2C Access Error (Clock Generator)

Error, error event

SEL List

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

2

MB PLL Lock Error (NDC30)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

3

MB PLL Lock Error (NDC31)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

4

MMR0 Power Failure

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

5

MMR1 Power Failure

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

6

MMR2 Power Failure

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

7

MMR3 Power Failure

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

8

MMR0 Removed (Wrong Operation)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

9

MMR1 Removed (Wrong Operation)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

A

MMR2 Removed (Wrong Operation)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

B

MMR3 Removed (Wrong Operation)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

C

CPU0 Configuration Error (Installation Rule)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

D

CPU1 Configuration Error (Installation Rule)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

E

CPU2 Configuration Error (Installation Rule)

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

7

 

F

Chassis Intrusion detected

Error, error event

 

 

 

 

 

logged to SEL

 

 

 

 

 

 

 

8

 

X

reserved

 

 

 

 

 

 

 

 

Intel® Server System SR9000MK4U Product Guide

175

Page 197
Image 197