Table 31. POST Codes Generated by the BMC and Logged at the Seven
Segment LED
| Code | Descriptions | Classification | Operation to | |
| Recover | ||||
|
|
|
|
| |
|
|
|
|
|
|
6 |
| A | PS0 Power Failure (Insufficient Resources) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
6 |
| B | PS1 Power Failure (Insufficient Resources) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
6 |
| C | CPU / MMR Overinstall (PS Insufficient | Error, error event |
|
|
|
| Resources) | logged to SEL |
|
|
|
|
|
|
|
6 |
| D | MB I2C Access Error (Sensor0) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
6 |
| E | MB I2C Access Error (Sensor1) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
6 |
| F | MB I2C Access Error (Voltage Margin0) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 0 | MB I2C Access Error (Voltage Margin1) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 1 | MB I2C Access Error (Clock Generator) | Error, error event | SEL List |
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 2 | MB PLL Lock Error (NDC30) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 3 | MB PLL Lock Error (NDC31) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 4 | MMR0 Power Failure | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 5 | MMR1 Power Failure | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 6 | MMR2 Power Failure | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 7 | MMR3 Power Failure | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 8 | MMR0 Removed (Wrong Operation) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| 9 | MMR1 Removed (Wrong Operation) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| A | MMR2 Removed (Wrong Operation) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| B | MMR3 Removed (Wrong Operation) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| C | CPU0 Configuration Error (Installation Rule) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| D | CPU1 Configuration Error (Installation Rule) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| E | CPU2 Configuration Error (Installation Rule) | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
7 |
| F | Chassis Intrusion detected | Error, error event |
|
|
|
|
| logged to SEL |
|
|
|
|
|
|
|
8 |
| X | reserved |
|
|
|
|
|
|
|
|
Intel® Server System SR9000MK4U Product Guide | 175 |