Internal Chassis Features
Power Supply Subsystem
The 12 V
The power supply module has two outputs, that is, +12 V and +5 Vsb. The standby voltages +5 Vsb is active anytime AC input power is applied to the power supply.
The power supply module is connected to the main board directly and can be used in 1+1 redundant mode.
Note: Two power supplies must be installed and plugged in when a 110 V outlet is used. Hot- swapping and redundancy are not available under this condition.
One power supply can be used when it is connected to a 220 VAC outlet. Under this condition, redundancy is available and a power supply can be
Table 6. 1390 W Power Supply Configuration
AC Input | Current | Redundancy |
| Remarks | |
See Note | |||||
|
|
|
| ||
|
|
|
|
| |
9.5 A | Supported | Supported | Restriction of loading is | ||
|
|
|
| needed. Two power | |
|
|
|
| supplies must be | |
|
|
|
| installed to enable | |
|
|
|
| redundancy and hot- | |
|
|
|
| swap. | |
|
|
|
|
| |
12 A | Not supported | Not supported | Restriction of loading is | ||
|
|
|
| needed. Two power | |
|
|
|
| supplies must be | |
|
|
|
| installed top operate the | |
|
|
|
| server system. | |
|
|
|
|
|
Note: This value is applied to one power supply.
12 | Intel® Server System SR9000MK4U Product Guide |