TC63 AT Command Set

4.10 AT+CMUX

s

Table 4.2:

Summary of AT commands with Different Behavior in Multiplex Mode

 

 

 

Command

 

Description

AT\Q

 

It is recommended to use hardware flow control (AT\Q3). XON/XOFF flow control

 

 

(AT\Q1) is not supported in Multiplex mode.

 

 

See note regarding AT\Qn settings stored with AT&W if Multiplex mode is active.

AT&V

 

Different default configurations on channels 1, 2 and 3.

AT&W

 

Different user profiles can be stored on each channel.

AT+IPR

 

Before you start Multiplex mode, it is recommended to set the ME to 57600 bps

 

 

(minimum should be 4800 bps). For GPRS we suggest to use 115200 bps or

 

 

230400 bps.

 

 

In Multiplex mode, the write command AT+IPR=<rate> will not change the bit rate

 

 

currently used, but the new bit rate will be stored and becomes active, when the

 

 

module is restarted.

AT+IPR=0

 

Multiplex mode cannot be activated while autobauding is enabled.

AT+CALA

 

On each channel an individual <text> message can be stored. but only one time

 

 

setting applies to all channels. This means an alarm <time> set on one of the

 

 

channels overwrites the time setting on all remaining channels. Therefore, the total

 

 

number of alarm events returned by the read command AT+CALA? will always be

 

 

<n>=0, no matter whether individual text messages are stored.

 

 

When the alarm is timed out and executed the ME sends the URC only on the

 

 

channel where the most recent alarm setting was made. The alarm time will be

 

 

reset to "00/01/01,00:00:00" on all channels.

AT+CMEE

 

Presentation mode can be separately configured for each channel.

AT+CNMA

 

If Multiplex mode is activated the +CNMI parameter will be set to zero on all chan-

 

 

nels, if one channel fails to acknowledge an incoming message within the required

 

 

time.

AT+CNMI

 

Phase 2+ parameters can only be used on one channel. The parameter for <mt>

 

 

and <ds> on the other channels have to be set to zero. If either a SM or a Status

 

 

Report is not acknowledged, all +CNMI parameter will be set to zero on all chan-

 

 

nels.

AT+CFUN

 

If the ME is in Multiplexer mode, it is not recommended to activate SLEEP mode

 

 

with AT+CFUN=<fun>. The best approach to properly control SLEEP mode in this

 

 

case is to issue the PSC messages described in [5], Section "Power saving control

 

 

(PSC)".

AT+CPMS

 

Parameter <mem3> will be the same on all instances, but the settings of <mem1>

 

 

and <mem2> may vary on each instance.

AT^SSDA

 

If one instance is set to <da>=1 and <mt>=1, then all other instances must be con-

 

 

figured for <mt>=0.

TC63_ATC_V00.490

Page 105 of 501

5/24/05

Confidential / Draft - Do not copy

 

 

Page 105
Image 105