TC63 AT Command Set

17.10 AT^SPBS

s

<internal-counter>(num)

0(&F)...maxindex

This parameter is only an internal parameter and cannot modified directly.

 

The internal counter will be reset to index 0 after a call to ATZ or AT&F.

Notes

The complete list of sorted entries can be retrieved using AT command AT^SPBG.

The command can be used for the phonebooks "SM", "FD", "ME" (cf. AT+CPBS).

AT^SPBG can be used only after the phonebook data from the SIM have been read successfully for the first time. Reading starts after successful SIM authentication has been performed, and may take up to 30 seconds depending on the SIM used. While the initial read process is in progress, an attempt to use any of the phone- book commands will result in "+CME Error: 14" (SIM busy).

We recommend to take advantage of the "^SSIM READY" URC. If enabled with AT^SSET, this URC notifies the user when SIM data are accessible after SIM PIN authentication. The URC will be delivered once the ME has completed reading data from the SIM card.

Examples

EXAMPLE 1

This example illustrates how to search down and up again using AT^SPBS=1 and 2:

at&f

OK at^spbs=1 ^SPBS:1,"+999999",145,"Arthur" ^SPBS:2,"+777777",145,"Bill" ^SPBS:3,"+888888",145,"Charlie"

OK at^spbs=1 ^SPBS:2,"+777777",145,"Bill" ^SPBS:3,"+888888",145,"Charlie" ^SPBS:4,"0304444444",129,"Esther"

OK at^spbs=1 ^SPBS:3,"+888888",145,"Charlie" ^SPBS:4,"0304444444",129,"Esther" ^SPBS:5,"03033333333",129,"Harry"

OK at^spbs=2 ^SPBS:2,"+777777",145,"Bill" ^SPBS:3,"+888888",145,"Charlie" ^SPBS:4,"0304444444",129,"Esther"

OK

EXAMPLE 2

First, AT&F is issued to make sure that AT^SPBS=1 starts from the first character in alphabetical order.

This example shows that when the last index in the sorted list has been reached, the internal counter over- flows to the first index.

 

 

at&f

 

Reset internal counter to 0.

 

 

 

 

OK

 

Step down one entry starting from (internal

 

 

at^spbs=2

 

 

 

^SPBS:33,"+49301234567",145,"TomTailor"

counter)=0 - overflow occurs.

 

 

 

 

^SPBS:1,"+999999",145,"Arthur"

 

 

 

 

 

 

^SPBS:2,"+777777",145,"Bill"

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

TC63_ATC_V00.490

Page 409 of 501

5/24/05

Confidential / Draft - Do not copy

 

 

 

 

Page 409
Image 409
Siemens TC63 manual Internal-counternum, At&f, Atspbs=2 SPBS33,+49301234567,145,TomTailor