TC63 AT Command Set

11.7 AT+CGEQMIN

s

Parameter Description

<cid>(num)

Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands.

1...2

<Traffic class>(num)

0

conversational

1

streaming

2

interactive

3

background

[4]

subscribed value

<Maximum bitrate UL>(num)

This parameter indicates the maximum number of kbits/s delivered to UMTS (up-link traffic) at a SAP. As an example a bitrate of 32kbit/s would be specified as 32 (e.g. AT+CGEQMIN=...,32,...).

[0]

subscribed value

1...63

 

64...128

(value needs to be divisible by 8 without remainder)

256

 

512

 

<Maximum bitrate DL>(num)

This parameter indicates the maximum number of kbits/s delivered by UMTS (down-link traffic) at a SAP. As an example a bitrate of 32kbit/s would be specified as 32 (e.g. AT+CGEQMIN=...,32,...).

[0]

subscribed value

1...63

 

64...256

(value needs to be divisible by 8 without remainder)

512

 

<Guaranteed bitrate UL>(num)

This parameter indicates the guaranteed number of kbits/s delivered to UMTS (up-link traffic) at a SAP (provided that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32 (e.g. AT+CGEQMIN=...,32,...).

[0]

subscribed value

1...63

 

64...128

(value needs to be divisible by 8 without remainder)

<Guaranteed bitrate DL>(num)

This parameter indicates the guaranteed number of kbits/s delivered by UMTS (down-link traffic) at a SAP (pro- vided that there is data to deliver). As an example a bitrate of 32kbit/s would be specified as 32 (e.g. AT+CGEQMIN=...,32,...).

[0]

subscribed value

1...63

 

64...256

(value needs to be divisible by 8 without remainder)

TC63_ATC_V00.490