TC63 AT Command Set

8.10 AT^SMONG

s

Note

For compatibility with earlier products and to support legacy applications, often any input character will stop the periodic output of the write command. But since this applies only in certain cases (depending on the set- tings of AT+IPR and AT+CMUX), it is recommended to always use "at" or "AT".

8.10.1AT^SMONG Cell Info Table

Example output for AT^SMONG:

GPRS Monitor

 

 

 

 

 

 

 

 

BCCH

G

PBCCH

PAT

MCC

MNC

NOM

TA

RAC

# Cell #

0637

1

-

4

234

05

2

00

0B

 

Columns of the cell info table:

 

 

 

 

 

 

 

 

 

 

 

 

 

Column

 

 

Description

 

 

 

 

BCCH

 

 

 

ARFCN of BCCH carrier

 

 

G

 

 

 

GPRS status:

 

 

 

 

0GPRS not available in currently used cell

1GPRS available in currently used cell

2GPRS attached

Note: During a voice call or CSD connection, GPRS services are not available, and con- sequently G=0 is displayed.

PBCCH

If PBCCH is present, indication of ARFCN, else ''-'' or if Frequency Hopping is used ''H''

PAT

Priority Access Threshold (GSM Rec. 04.08 / 10.5.2.37b)

 

0

Packet access is not allowed in the cell

 

1

Spare, shall be interpreted as "000" (packet access not allowed)

 

2

Spare, shall be interpreted as "000" (packet access not allowed)

 

3

Packet access is allowed for priority level 1

 

4

Packet access is allowed for priority level 1 to 2

MCC

Mobile Country Code

MNC

Mobile Network Code

NOM

Network Operation Mode (1...3)

TA

Timing Advance Value

RAC

Routing Area Code (as hexadecimal value)

TC63_ATC_V00.490

Page 199 of 501

5/24/05

Confidential / Draft - Do not copy

 

 

Page 199
Image 199