TC63 AT Command Set

2. Configuration Commands

s

2.Configuration Commands

The AT Commands described in this chapter allow the external application to determine the TC63's behaviour under various conditions.

2.1

AT&F Set all current parameters to manufacturer defaults

AT&F sets all current parameters to the manufacturer defined profile. All defined GPRS contexts which are not activated or not online will be undefined (see AT+CGDCONT).

Syntax

Exec Command

AT&F[<value>]

Response(s)

OK

Reference(s)

V.250

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

! % % % % % % ! % !

Parameter Description

<value>(num)

[0]

Set all TA parameters to manufacturer defaults

Notes

List of parameters reset to manufacturer default can be found in Section 21.6, Factory Default Set- tings Restorable with AT&F.

In addition to the default profile, you can store an individual one with AT&W. To alternate between the two pro- files enter either ATZ (loads user profile) or AT&F (restores factory profile).

Every ongoing or incoming call will be terminated.