TC63 AT Command Set

18.10 AT^SNFD

s

18.10AT^SNFD Set audio parameters to manufacturer default values

AT^SNFD sets the active audio parameters to manufacturer defined default values. The restored values are:

AT^SNFA: <atten>

AT^SNFI: <inBbcGain>, <inCalibrate>

AT^SNFO: <outBbcGain>, <outCalibrate>[0 to 4], <sideTone>

AT^SAIC: <io>, <mic>, <ep>

AT^SNFS: <audMode>

Syntax

Test Command

AT^SNFD=?

Response(s)

OK

Exec Command

AT^SNFD

Response(s)

OK

Reference(s)

SIEMENS

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

! % % % % % % ! % !

Note

Remember that the factory set audio mode 1 is fixed to <outStep>=4. Consequently, AT^SNFD restores <audMode> together with <outStep>=4, but does not affect the values of <outStep> currently selected in audio modes 2 - 6. This means, if <audMode>=1, the read commands AT^SNFO, AT^SNFV and AT+CLVL will always deliver <outStep>=4. In all other modes the <outStep> value is retained until explicitly changed.

TC63_ATC_V00.490

Page 421 of 501

5/24/05

Confidential / Draft - Do not copy

 

 

Page 421
Image 421
Siemens TC63 manual Atsnfd Set audio parameters to manufacturer default values, Atsnfd=?