TC63 AT Command Set

3.1 AT+CMER

s

Parameter Description

<mode>(num)

0(&F)

Discard "+CIEV" and "^SLCC" URCs.

1

Discard "+CIEV" and "^SLCC" URCs when TA-TE link is reserved, e.g. in

 

online data mode. Otherwise they are forwarded directly to the TE.

2

Buffer "+CIEV" and "^SLCC" URCs in the TA while TA-TE link is reserved, e.g.

 

in online data mode, and flush them to the TE afterwards. Otherwise they are

 

forwarded directly to the TE.

3

Forward "+CIEV" and "^SLCC" URCs directly to the TE. If TC63 is in online

 

data mode, URCs are signaled via sending BREAK (100ms) and stored in a

 

buffer. Once it is back in command mode e.g. after +++ was entered, all URCs

 

stored in the buffer will be output.

 

 

<keyp>(num)

 

0(&F)

Keypad event reporting is not supported by TC63.

 

 

<disp>(num)

 

0(&F)

Display event reporting is not supported by TC63.

 

 

<ind>(num)

 

0(&F)

Disable indicator event reporting.

2

Enable indicator event reporting.

 

 

<bfr>(num)

 

0(&F)

TA buffer of URCs defined within this command is cleared when <mode> 1..3

 

is entered.

<indDescr>(str)

Name of indicator; for a list of all supported indicators please refer to AT+CIND and AT^SIND.

<indValue>(num)

Value of indicator; for a list of all values for the supported indicators please refer to AT+CIND and AT^SIND.

Note

If the ME operates on different instances (MUX channels 1, 2, 3 or ASC0/ASC1) avoid different settings for routing and indicating SMS. For example, if messages shall be routed directly to one instance of the TE (set with AT+CNMI, AT^SSDA), it is not possible to activate the presentation of URCs with AT+CMER or AT+CNMI on another instance. Any attempt to activate settings that conflict with existing settings on another interface, will result in CME ERROR, or accordingly CMS ERROR.

TC63_ATC_V00.490

Page 67 of 501

5/24/05

Confidential / Draft - Do not copy

 

 

Page 67
Image 67
Siemens TC63 manual Modenum, Keypnum, Dispnum, Indnum, Bfrnum, IndDescrstr, IndValuenum