20.2ATS3 Set command line termination character

The ATS3 command determines the character recognized by the TA to terminate an incoming command line.

Syntax

Read Command

ATS3?

Response(s)

<n>

OK

Write Command

ATS3=<n>

Response(s)

OK

ERROR

Reference(s)

V.250

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

! % % % % % % ! % !

Parameter Description

<n>(num)(&W)(&V)

command line termination character 000...13(&F)...127

Notes

Using a value other than the default 13 may cause problems when entering commands.

Whenever you change the setting take into account that the new value has no effect on the URC "^SHUT- DOWN".