11.8 AT+CGEQREQ

s

<Maximum SDU size>(num)

This parameter indicates the maximum allowed SDU size in octets.

[0]

subscribed value

10...1520

(value needs to be divisible by 10 without remainder)

1502

 

<SDU error ratio>(str)

This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous. SDU error ratio is defined only for conforming traffic. The value is specified as "mEe". As an example a target SDU error ratio of 5*10-3would be specified as "5E3" (e.g. AT+CGEQREQ=...,"5E3",...).

[“0E0“]

subscribed value

“1E2“

 

“7E3“

 

“1E3“

 

“1E4“

 

“1E5“

 

“1E6“

 

“1E1“

 

<Residual bit error ratio>(str)

This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested, Residual bit error ratio indicates the bit error ratio in the delivered SDUs. The value is specified as "mEe". As an example a target residual bit error ratio of 5*10-3would be specified as "5E3" (e.g. AT+CGEQREQ=...,"5E3",...).

[“0E0“]

subscribed value

“5E2“

 

“1E2“

 

“5E3“

 

“4E3“

 

“1E3“

 

“1E4“

 

“1E5“

 

“1E6“

 

“6E8“

 

<Delivery of erroneous SDUs>(num)

This parameter indicates whether SDUs detected as erroneous shall be delivered or not.

0

no

1

yes

2

no detect

[3]

subscribed value

TC63_ATC_V00.490