TC63 AT Command Set

3.3 AT^SIND

s

 

manual network selection fails and the module automatically falls back to the

 

previous network the NITZ values cannot be recalled. Nevertheless an indi-

 

cated time zone is valid until a new MMI/GMMI will trigger another NITZ indi-

 

cation.

“band“

Currently selected frequency band or band combination.

 

1...14 Identical with <rbc> of AT^SCFG. The value indicates the band(s) cur-

 

rently available for network selection, depending on the network config-

 

uration either a single band or a dualband combination. The URC

 

appears whenever the status of the currently available band(s)

 

changes, for example after using the AT^SCFG command to change

 

the "Radio/Band" parameters <rba> or <rbp>. Please see AT^SCFG

 

for further detail about the feature "Radio/Band" selection.

<indValue>(num)

Integer type value in the range stated above for the corresponding <indDescr>.

Notes specific to the EONS feature:

If the indicator is "eons", the <indValue> is a type associated to the operator name according to GSM 22.101 [25]. This type depends on the source of the operator name.

Priority of types associated to the operator names is defined as follows (the type listed first has the highest pri- ority). If a type cannot be indicated the next one will be used.

0

Not registered.

1

EF-OPL and EF-PNN (alphanumeric format, can contain up to 24 characters.)

2

Operator Name String in long and short format according to Common PCN

 

Handset Specification (CPHS) [26] (alphanumeric format, can contain up to 16

 

characters).

3

Name information received by the NITZ service long and short form (alphanu-

 

meric format, can contain up to 16 characters). The short form will be displayed

4

only if EFOPShort from CPHS is available.

Any operator name stored internal to the ME (alphanumeric format, can con-

 

tain up to 16 characters).

5

Broadcast MCC-MNC (numeric format which consists of a 3-digit country code

 

plus a 2- or 3-digit network code).

The name information received by the NITZ service (type 3) will be saved in the non-volatile RAM. It replaces the operator name of the registered PLMN (type 4) or its numeric form (type 5) stored in the ME. However, when after restart the ME registers to another PLMN that is not equal to the saved NITZ name information, the NITZ name information must be invalidated.

If the type is 2, 4 or 5, AT+COPS with the appropriate <mode> displays the same operator name. <mode>(num)

0

Indicator is deregistered, i.e. no such indicator event report (URC) will be

 

issued. <mode>=0 is power-up and factory default of indicators defined by

 

AT^SIND only.

1

Indicator is registered.

 

• Indicator event reports are controlled via AT+CMER.

 

• All indicators can be registered or deregistered via AT^SIND, but different

 

default settings apply: Power-up and factory default of the indicators sup-

 

ported by AT+CIND is <mode>=1, while, as stated above, indicators defined

 

by AT^SIND only are set to <mode>=0.

2

Query the registration status and the current value of a single indicator type.

<adnEntry>(num)

ADN phonebook record number on the SIM.

TC63_ATC_V00.490

Page 75 of 501

5/24/05

Confidential / Draft - Do not copy

 

 

Page 75
Image 75
Siemens TC63 manual Atsind only, AdnEntrynum