UPGRADING FIRMWARE VIA THE SERIAL PORT

power on or rebooting the switch. Screen text similar to that shown below displays:

File NameS/Up Type Size Create Time

--------------------------------- ---- ---- ---------- --------

$logfile_1

0

3

64

00:00:07

$logfile_2

0

3

64

00:00:12

diag_0070

0

1

96500

00:06:37

diag_0074

1

1

97780

00:00:05

run_03024

0

2

1121956

00:21:41

run_10020

1

2

1124416

00:00:10

---------------------------------

---- ---- ---------- --------

[X]modem Download [D]elete File

[S]et Startup File

 

[R]eturn to Factory Default

[C]hange Baudrate

[Q]uit

Select>

 

 

5.Press <c> to change the baud rate of the switch’s serial connection.

6.Press <b> to select the option for 115200 baud.

7.There are two baud rate settings available, 9600 and 115200. Using the higher baud rate minimizes the time required to download firmware code files.

8.Set your PC’s terminal emulation software to match the 115200 baud rate. Press <Enter> to reset communications with the switch.

Select>

Change baudrate [A]9600 [B]115200

Baudrate set to 115200

9.Check that the switch has sufficient flash memory space for the new code file before starting the download.

10.You can store a maximum of only two runtime and two diagnostic code files in the switch’s flash memory. Use the [D]elete File command to remove a runtime or diagnostic file.

11.Press <x> to start downloading the new code file.

B-2

Page 600
Image 600
SMC Networks SMC6724L3 manual Upgrading Firmware VIA the Serial Port