SMC Networks SMC6724L3 manual 178, Specifying Network Interfaces for RIP

Models: SMC6724L3

1 618
Download 618 pages 36.53 Kb
Page 226
Image 226

CONFIGURING THE SWITCH

CLI - This example sets the router to use RIP Version 2, and sets the basic timer to 15 seconds.

Console(config)#router rip

4-231

Console(config-router)#version 2

4-235

Console(config-router)#timers basic 15

4-232

Console(config-router)#end

 

Console#show rip globals

4-242

RIP Process: Enabled

Update Time in Seconds: 15

Number of Route Change: 0

Number of Queries: 1

Console#

Specifying Network Interfaces for RIP

You must specify network interfaces that will be included in the RIP routing process.

Command Usage

RIP only sends updates to interfaces specified by this command.

Subnet addresses are interpreted as class A, B or C, based on the first field in the specified address. In other words, if a subnet address nnn.xxx.xxx.xxx is entered, the first field (nnn) determines the class:

0 - 127 is class A, and only the first field in the network address is used.

128 - 191 is class B, and the first two fields in the network address are used.

192 - 223 is class C, and the first three fields in the network address are used.

Command Attributes

Subnet Address – IP address of a network directly connected to this router.