LINE COMMANDS

Command Mode

Line Configuration

Command Usage

When the logon attempt threshold is reached, the system interface becomes silent for a specified amount of time before allowing the next logon attempt. (Use the silent-time command to set this interval.) When this threshold is reached for Telnet, the Telnet logon interface shuts down.

This command applies to both the local console and Telnet connections.

Example

To set the password threshold to five attempts, enter this command:

Console(config-line)#password-thresh 5

Console(config-line)#

Related Commands

silent-time (3-79)

silent-time

Use this command to set the amount of time the management console is inaccessible after the number of unsuccessful logon attempts exceeds the threshold set by the password-threshcommand. Use the no form to remove the silent time value.

Syntax

silent-time seconds no silent-time

seconds - The number of seconds to disable console response. (Range: 0-65535; 0: no silent-time)

3-79

Page 223
Image 223
SMC Networks TigerSwitch 100 manual Syntax Silent-time seconds no silent-time