Toshiba HWS-802H-E, HWS-802XWHT6-E, HWS-802XWHM3-E, HWS-3001CSHM3-E(-UK) Auto Curve Setting

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 111
Image 111
4. Auto Curve Setting

4. Auto Curve Setting

FC code setting can make flexible Auto-Curve settings.

<Preparation>

1 Press the TEST Manual background and SET Manual background and SELECT Manual background buttons at the same time for 4 seconds or longer. (See display Manual background )

(Make sure that no operation is in progress.)

2 Specify an item code (FC) from among 29 to 2F with the

TEMP. Manual backgroundManual background button for temperature setting.

3 Set data with the TIME Manual backgroundManual background button for timer setting.

4 Press the SET Manual background button. (If Manual background lights, the status is confirmed)

5 Repeat 2 through 4 for each item.

6 Pressing the TEST Manual background button moves the unit to the normal stop state.

2

3

4

6

1

FC

Item

 

Details

Fist shipment

 

 

 

 

 

 

29

Outside air temperature T1 temperature

-0015: -15°C

-

0000: 0°C

-0010: -10°C

 

 

 

 

 

 

2B

Outside air temperature T3 temperature

0000: 0°C

-

0015: 15°C

0010: 10°C

 

 

 

 

 

 

2C

Set temperature A with outside air temperature of -20°C

0020: 20°C

-

0055: 55°C

0040: 40°C

 

 

 

 

 

 

2D

Set temperature B with outside air temperature of T1

0020: 20°C

-

0055: 55°C

0035: 35°C

 

 

 

 

 

 

2E

Set temperature C with outside air temperature of 0°C

0020: 20°C

-

0055: 55°C

0030: 30°C

 

 

 

 

 

 

2F

Set temperature D with outside air temperature of T3

0020: 20°C

-

0055: 55°C

0025: 25°C

 

 

 

 

 

 

30

Set temperature E with outside air temperature of 20°C

0020: 20°C

-

0055: 55°C

0020: 20°C

 

 

 

 

 

 

31

Zone2 ratio with Zone1 as Auto

0000: 0%

-

0100: 100%

0080: 80%

 

 

 

 

 

 

TSC-F

Set temperature (Manual background)

A(40)

B(35)

C(30)

D(25)

E(20)

-20 T1 (-10)

Auto-Curve

Temperature shift

Default Setting

0 T3 20

(+10)

Outside

 

air temperature (TO)

Auto-Curve temperature shift

Without Auto-Curve individually set, the set temperature can be shifted in the range of ±5k of the current setting. (The set temperature is valid only when Auto operation is in progress.)

1 Press the AUTO TEMP Manual background button for 4 seconds or longer. (See display Manual background )

 

(The remote controller FC setting screen appears.)

2

 

 

2

 

 

 

 

 

Set a temperature shift range with the TEMP.

 

 

 

 

button for temperature setting. (-5k to 5k)

 

 

 

3

Press the SET

button. (If

lights, the status is

 

 

 

 

confirmed)

 

 

3

4

1

4

Pressing the TEST

button moves the unit to the normal

 

 

 

stop state.