[A12] Error Heating or Hot water supply heater failure

Restart

Operation starts under 10 TWI 20°C

Freeze prevention control is detected once

Heater backup operation Heating: Booster heater

Hot water supply: Hot water cylinder heater

After 1 hour since heater operation started, neither TWI 15°C

nor TTW 20°C is met

Water heat

No

exchanger board DPSW11-1,2

 

is ON

 

Yes

 

Backup heater or

No

hot water cylinder terminal

 

has 230ACV ( ± 23V)

 

A12 abnormality detection

Set water heat board DPSW11-1,2 to ON

Yes

Power is connect

No

Place electric wire for

backup heater

 

to backup heater or hot water

 

 

Place electric wire for

 

cylinder terminal

 

 

 

hot water cylinder

 

 

 

 

 

 

Yes

 

 

 

 

 

Set breaker for backup

 

 

 

 

heater to ON

 

 

 

 

Set breaker for hot water

 

 

 

 

 

 

 

 

cylinder to ON

 

 

 

 

or check indoor wiring

Backup heater element

No

 

 

is conductive

(Backup heater NG)

Yes

 

 

Hot water

No

 

 

cylinder heater element

 

(Hot water cylinder heater NG)

 

is conductive

 

Yes

 

 

TWI, TTW sensor

 

No

 

characteristics are

 

 

(See characteristic table in page 101)

 

normal

 

 

 

Yes

 

 

 

 

 

Replace water heat

 

 

exchange control board

 

 

 

 

 

Replace booster heater unit and safety valve

Replace hot water cylinder heater

(Refer to hot water cylinder guide)

Replace TWI or TTW sensor

83

Page 84
Image 84
Toshiba HWS-2101CSHM3-E(-UK), HWS-802XWHT6-E, HWS-802H-E, HWS-1402H-E A12 Error Heating or Hot water supply heater failure