Toshiba HWS-2101CSHM3-E(-UK), HWS-802XWHT6-E, HWS-802H-E, HWS-802XWHM3-E, HWS-3001CSHM3-E(-UK) name

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 144
Image 144
Manual background

No.

Exchange parts

 

 

Work procedure

 

 

 

 

Remarks

 

name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Compressor

2. Attach the compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor lead

1)Attach the compressor in the reverse order of the

 

Compressor

 

 

Wind ferrite core with

 

 

 

 

 

removal.

 

lead

 

 

compressor lead for 4 times.

 

 

 

 

 

Note)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Be sure to replace the compressor lead after the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

compressor replacement. (Compressor lead

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

spare parts code: 43160591)

 

 

 

 

 

 

 

 

 

 

 

 

Ferrite core

 

 

 

 

At this time, wind the ferrite core with the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

compressor lead for 4 times.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bind the compressor lead that is long with a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commercially available binding tie. When doing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

this, be careful for the compressor lead not to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

contact the discharge pipe.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 50

 

 

Bind the lead at 2 positions

 

 

 

 

• Fix the removed sensors and pulse motor valve

 

 

 

 

 

 

 

 

(Compressor lead

 

 

with a commercially

 

 

 

 

coil lead to the outlet and suction pipes through

 

 

 

 

 

 

 

 

positioning standard)

 

available binding tie

 

 

 

 

the piping cover by using a binding tie. At this

 

 

 

 

 

 

Place soundproofing board (Outward winding)

 

 

 

time, be careful for the sensors and pulse motor

 

 

 

valve coil lead not to contact the discharge pipe.

through between suction pipe and accumulator

 

 

 

(To fix the sensors and leads, use the black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction pipe

 

 

 

 

 

piping cover for heat resistance and a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commercially available binding tie for heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

resistance.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Attach the soundproofing board (Inward

 

Accumulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

winding, Outward winding), as shown in the right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

figure, through between the compressor and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between the piping and parting board.

 

Header pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Place the compressor lead and the compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

case thermostat so that they fall into between

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the inward winding and outward winding of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

soundproofing board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Place soundproofing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

board (Inward winding)

 

 

Overlap soundproofing

 

 

 

 

 

 

 

 

 

 

 

 

through between suction

 

board (Outward winding)

 

 

 

 

 

 

 

 

 

 

 

pipe and header pipe

 

 

at this position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Soundproofing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

board (Upper)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Piping cover, Binding tie, TS sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet pipe

 

 

 

 

 

 

 

 

 

 

Soundproofing board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Outward winding)

 

 

 

Do not make gap between soundproofing boards (Upper and Outward winding)

 

 

 

Black piping cover for heat resistance,

 

 

 

and Binding tie for heat resistance

 

 

 

Sensors (TL, TO, TE, TD, TS)

 

 

 

Pulse motor valve coil lead

 

 

 

Keep sensors away

 

 

 

for not contacting outlet pipe

 

 

 

 

 

 

Suction pipe

 

Pulse motor valve coil lead

 

Piping cover, Binding tie

 

 

Sensors (TL, TO, TE, TS)

 

 

Pulse motor valve coil lead

 

 

143

Page 144
Image 144
Toshiba HWS-2101CSHM3-E(-UK), HWS-802XWHT6-E, HWS-802H-E, HWS-802XWHM3-E, HWS-3001CSHM3-E(-UK), HWS-1402H-E service manual name