Exchange parts name

No.

Exchange parts name

Work procedure

Remarks

 

 

 

 

 

 

 

 

 

 

9

Expansion vessel

 

 

 

 

 

 

Expansion vessel

To replace a water circuit part, first close the water

 

 

 

 

 

 

 

 

supply source valve and the valve of water pipe

 

 

 

 

 

 

connected to the hydro unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)Perform the step 1-1, step 5, 6, and 7.

 

 

 

 

2)Remove the fixed band of the expansion vessel.

 

 

 

 

(ST1T Ø4 × 8, 4 screws)

 

 

 

 

3)Remove the expansion vessel connection (three-

 

 

 

 

piece flare nut).

Expansion vessel

 

 

 

 

 

 

 

 

 

 

Replace the packing to new one when installing the

Fixed band

 

 

 

 

 

 

expansion vessel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part code

 

Service parts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37595721

 

Service packing assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After the expansion vessel replacement repair,

 

 

 

 

 

 

open the water supply source valve and water

 

 

 

 

 

piping valve to pass water through the hydro unit,

 

 

 

 

 

and check that the expasion vessel connection has

 

 

 

 

 

no water leakage.

 

Replace the packing to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

new one when installing

 

 

 

 

 

 

 

 

the expansion vessel.

 

 

 

 

 

 

 

 

 

 

10

Relief valve

 

 

 

 

 

 

 

To replace a water circuit part, first close the water

 

 

Relief valve connecting hose

 

 

 

 

 

 

 

supply source valve and the valve of water pipe

 

Internal diameter: 15mm, Length: 850L

 

 

 

connected to the hydro unit.

 

 

Relief valve

 

 

 

 

 

 

 

 

 

 

1)Perform the step 1-1, step 5, 6, and 7.

 

 

 

 

 

 

2)Remove the quick fastener.

 

 

 

 

3)Remove the relief valve by pulling it upward.

 

 

 

 

 

 

 

 

 

The relief valve connection uses an O ring for water

 

 

 

 

 

 

seal. Be careful not to scratch the O ring; otherwise,

 

 

 

 

 

water leakage may occur.

 

 

 

 

 

 

 

Quick

 

 

 

 

 

After the relief valve replacement repair, open the

 

 

 

 

water supply source valve and water piping valve to

 

fastener

 

 

pass water through the hydro unit, and check that

 

 

 

 

 

the relief valve connection has no water leakage.

 

 

 

 

 

 

 

 

 

 

 

 

 

11 Air vent valve

To replace a water circuit part, first close the water

Air vent valve

supply source valve and the valve of water pipe

 

connected to the hydro unit.

 

 

 

1)Perform the step 1-1, step 5, 6, and 7.

 

2)Remove the air vent valve.

 

 

 

After the air vent valve replacement repair, open the

 

water supply source valve and water piping valve to

 

pass water through the hydro unit, and check that

 

the air vent valve connection has no water leakage.

 

 

 