Toshiba HWS-1402H-E Key Electric Component Rating, Hydro Unit, HWS-802XWHM3-E, 802XWHT6-E

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 25
Image 25

6

Key Electric Component Rating

6-1. Hydro Unit

 

 

 

 

HWS-802XWHM3-E, 802XWHT6-E

 

 

 

 

 

 

 

 

 

 

 

Model name

 

 

No.

Component name

 

 

Type name

Rating

M3-E

T6-E

 

 

 

 

 

 

 

 

 

 

1

Circulating pump

O

O

UPS025-65 K 130

AC230 V 0.54 A (MAX)

 

 

 

 

 

 

2

Backup heater 6 kW

O

O

AC 400 V (3N) 6 kW (AC230 V 3 kW

 

compatible)

 

 

 

 

 

 

 

 

 

 

 

3

Backup heater 9 kW

 

 

AC400V (3N) 9 kW

 

 

 

 

 

 

 

Water heat exchange

 

 

 

10 kΩ (25°C)

4

temperature sensor

O

O

 

 

(TC sensor)

 

 

 

 

 

 

 

 

 

 

5

Water inlet temperature sensor

O

O

10 kΩ (25°C)

(TWI sensor)

 

 

 

 

 

 

 

 

 

 

 

 

6

Water outlet temperature sensor

O

O

10 kΩ (25°C)

(TWO sensor)

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater outlet water temperature

 

 

 

10 kΩ (25°C)

7

sensor

O

O

 

 

(THO sensor)

 

 

 

 

 

 

 

 

 

 

8

Floor inlet temperature sensor

O

O

10 kΩ (25°C)

(TFI sensor)

 

 

 

 

 

 

 

 

 

 

 

 

9

Pressure switch

O

O

Operating pressure 4.15 MPa +0 -0.3 MPa

 

 

 

 

 

 

10

Low pressure sensor

O

O

Operating pressure 0.20 MPa

 

 

 

 

 

 

11

Bimetal thermostat (auto)

O

O

Operating temperature 75±3°C DC42 V / 0.2 A

 

 

 

 

 

 

12

Bimetal thermostat (single

O

O

Operating temperature 95±5°C AC250 V / 16 A

operation)

 

 

 

 

 

 

 

 

 

 

 

 

13

Flow switch

O

O

Operating flowing quantity 13 L/min

 

 

 

 

 

 

14

Output board (OP)

OP

OP

TCB-PCIN3E

AC230 V 0.5 A DC24 V 1 A

 

 

 

 

 

 

15

Input board (OP)

OP

OP

TCB-PCM03E

Contact input

 

 

 

 

 

 

16

Remote control

O

O

HWS-AMS11E

 

 

 

 

 

 

 

17

Water 3-way valve terminal

O

O

AC230 V 0.1 A

 

2Wire, 3Wire SPST, SPDT type mountable

 

 

 

 

 

 

 

 

 

 

 

18

Water 2-way valve terminal

O

O

AC230 V 0.1 A 2Wire type mountable

 

 

 

 

 

 

19

Mixing valve terminal

O

O

AC230 V 0.1 A

 

3Wire SPST, SPDT type mountable

 

 

 

 

 

 

 

 

 

 

 

20

Circulating pump terminal

O

O

AC230 V 1.0 A

 

 

 

 

 

 

21

Booster heater terminal

O

O

AC230 V 1.0 A

 

 

 

 

 

 

22

Fuse

O

O

AC 250 V 30 A

 

 

 

 

 

 

O ········· Applied

OP·······Optional accessory

24

Page 25
Image 25
Toshiba HWS-1402H-E, HWS-802XWHT6-E, HWS-802H-E Key Electric Component Rating, Hydro Unit, HWS-802XWHM3-E, 802XWHT6-E