7. Frost Protection Setting

6-2. How to start and cancel schedule operation

<Operation start>

Without schedule operation set, press the remote controller SCHEDULE 2,3 1,3 button. Manual background blinks.

Pressing the SET button during the 5-second blinking changes Manual background to lit, and the schedule operation starts.

<Operation cancel>

With schedule operation set, press the remote controller SCHEDULE Manual background button. Manual background blinks.

Pressing the CL Manual background button during the 5-second blinking causes Manual background to put out, and the schedule operation is cancelled.

7. Frost Protection Setting

This setting keeps a room with weak heating when users are not home for long hours.

1 Press the ZONE1,2 Manual background button to start a heating operation.

(This is available only for a normal heating operation.)

(No frost protection setting is provided to hot water supply and cooling.)

2 Pressing the FORST PROTECTION Manual background button displays the Manual background symbol and "F" for temperature setting. (See display Manual background )

The heating operation of 15°C is set.In FC_3B in 2-2 section, the set temperature can be changed in the range of 10 to 55°C.

3 Pressing the FORST PROTECTION Manual background button makes Manual background disappear, and the set temperature returns to the normal heating

temperature. (Pressing the ZONE1,2 Manual background button ends both the frost protection and the heating operation.)

2,3 1,3