Toshiba HWS-802XWHM3-E, HWS-802XWHT6-E, HWS-802H-E, HWS-3001CSHM3-E(-UK) Cooling operation

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 42
Image 42
3) Cooling operation

Item

 

 

 

Operation flow and applicable data, etc.

 

 

 

 

 

 

 

 

 

8-2.

3) Cooling operation

 

 

 

Operation

Pressing the [ZONE1, 2] button and then [OPERATION MODE] starts a cooling operation.

 

Mode and

 

 

 

 

 

 

 

Control Method

1) Operation start condition

 

TWI

 

Pressing the [ZONE1, 2] button and then [OPERATION MODE]

 

 

 

 

Heat pump operation

 

starts a cooling operation.

 

 

 

 

 

(cooling)

 

 

 

 

 

TSC_F

 

 

 

 

 

 

 

d zone

 

2) Operation mode selection

(Temperature set with

 

Diff : 2k

 

An operation mode is determined according to the temperature

remote controller)

 

 

 

e zone

 

of TWI sensor.

TSC_F

 

Thermostat off operation

 

Heat pump operation selection *1 *2

 

 

 

 

When TWI

 

TSC_F (d zone in the right figure) is met, the heat

 

 

 

 

 

 

 

 

 

 

 

pump operation is selected.

 

TSC is a cooling temperature

 

• Thermostat status "OFF"

 

set with the remote controller

 

 

When TWI < TSC_F (e zone in the right figure) is met, the

 

 

 

 

 

thermostat status "OFF" is selected.

 

 

 

 

3) Operation stop condition

 

 

 

 

When either of the following conditions is met, the cooling

 

 

 

 

operation stops.

 

 

 

 

The remote controller gives a stop instruction.

 

 

 

 

The operation is switched to heating.

 

 

 

*1: When the outside temperature is 10°C or below, cooling does not start even if the TWI temperature falls into "d zone".

Related FC

FC No.

Setting item

Default

Setting available range

 

 

 

 

02

Cooling mode availability

1: No

0: Yes

 

 

 

 

18

Upper limit of cooling setting temperature

25

18-30°C

 

 

 

 

19

Lower limit of cooling setting temperature

10

10-18°C

 

 

 

 

4) Simultaneous operations of "hot water supply" and "heating"

TO

 

 

 

At the time of "Hot water supply" and "Heating" simultaneous

 

 

 

operation, the operation mode is select as follows depending on

 

Hot water

f zone

 

 

the outside air temperature.

 

 

 

supply heat

 

 

 

 

 

 

 

 

pump priority

Diff : 5deg

f zone Operation with hot water supply priority

D

operation

 

 

 

A heat pump operation is performed in the hot water supply side,

 

g zone

 

 

(Note) Heating heat

 

 

and a heating operation in the heating side.

 

 

 

 

 

 

 

pump priority

 

g zone Operation with heating priority

 

 

 

Diff : 5deg

 

 

 

operation

 

 

A heat pump operation is performed in the heating side, and a

-20

 

 

 

 

 

 

 

heating operation in the hot water supply side.

 

 

 

 

 

 

 

Operation mode by zone

 

 

 

Heater operation

h zone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

Hot water supply side

 

Heating side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

f

Heat pump *

 

Stop *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

g

Heater

 

Heat pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h

Heater

 

Heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Note that after a heat pump operation for "Hot water supply" is selected in f zone, when the operation moves to a heater operation for "hot water" and then 5 minutes has passed (Hot water supply operation in b zone), the operation mode changes as follows.

 

 

Zone

 

 

Hot water supply side

 

Heating side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

f'

 

 

 

Heater

 

Heat pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When TTW

 

45°C (FC: changeable) is met, the operation ends f' zone and returns to f zone.

 

Related FC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FC No.

 

 

 

Setting item

 

 

Default

Setting available range

 

 

 

 

 

 

 

 

 

07

Maximum HP operation time in “hot water supply” + “heating

 

30 min

0-120min

 

mode”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Priority mode switch temperature (D)

 

 

0

-20-20°C

 

 

 

 

 

 

 

 

 

 

 

 

*Note: When user selects “hot water supply” and “ZONE1,2”, and Heat pump selects hot water supply mode, the Maximum operating time of heat pump is 30 mins.

41

Page 42
Image 42
Toshiba HWS-802XWHM3-E, HWS-802XWHT6-E, HWS-802H-E, HWS-3001CSHM3-E(-UK), HWS-2101CSHM3-E(-UK), HWS-1402H-E Cooling operation