No.

Exchange parts

Work procedure

 

 

 

 

Remarks

 

name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 Compressor

1. Remove defective compressor

Piping panel (Front)

 

 

Compressor lead

1)Perform refrigerant gas recovery.

 

 

 

 

 

 

 

 

 

 

2)Perform the step 1-1 and step 3.

 

 

 

 

 

 

 

 

3) Remove the piping panel (Front).

 

 

 

 

 

 

 

 

Remove screws of the piping panel (Front) and

 

 

 

 

 

 

 

 

bottom board.

 

 

 

 

 

 

 

 

(Hex Ø4 × 10, 2 screws)

 

 

 

 

 

 

 

 

Remove screws of the piping panel (Front and

 

 

 

 

Piping panel (Back)

 

 

Back).

 

 

 

 

 

 

 

 

 

 

 

 

Piping cover

TD sensor

 

 

(Hex Ø4 × 10, 1 screws)

 

 

 

 

 

 

Binding tie

 

 

 

4)Remove the piping panel (Back).

 

 

 

Remove screws of the piping panel (Back) and

(for heat resistance)

 

 

 

 

 

 

 

 

 

 

 

bottom board.

 

 

 

 

 

 

 

 

(Hex Ø4 × 10, 2 screws)

Compressor lead

 

 

 

5)Remove the soundproofing board. (Upper, Inward

 

 

 

 

 

 

 

 

winding, Outward winding)

 

 

 

 

 

 

 

 

6)Remove the compressor terminal cover, and then

 

 

 

 

 

 

 

 

remove the compressor lead and compressor

 

 

 

 

 

 

 

 

case thermostat.

 

 

 

 

Compressor case thermostat

 

 

7)Remove the TD sensor fixed to the discharge

Control board

 

 

 

piping.

 

 

 

 

 

 

 

 

8)Remove the compressor lead. (Leave the ferrite

 

 

 

 

 

 

 

 

core attached to the electric parts box.)

 

 

 

 

 

 

 

 

Control board U: CN200 Red

 

 

 

 

 

 

 

 

V: CN201 White

 

 

 

 

 

 

 

 

W: CN202 Black

 

 

 

 

 

 

 

 

9)Remove the outlet and suction pipes connected to

 

 

 

 

Compressor lead

 

 

the compressor by using a burner.

 

 

 

 

 

 

 

 

WARNING

Compressor lead

 

 

 

 

 

 

 

 

 

 

 

When removing the piping by burning the solder,

 

 

 

 

 

 

 

 

take enough care for a fire going off at the

 

 

 

 

 

 

 

 

moment the wax melts if oil remains inside the

 

 

 

 

 

 

 

 

piping.

 

 

 

 

 

 

 

 

Note)

 

 

 

 

 

 

 

 

Do not make fire flame contact with the 4-way

 

 

 

 

 

 

 

 

valve and pulse motor valve.

 

 

 

 

 

 

 

 

(This may cause an operation failure.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10) Pull out the discharge and suction pipes of the

 

Ferrite core

 

 

 

 

 

 

 

 

 

 

 

 

 

refrigerant cycle upward.

 

 

 

 

 

 

 

 

11) Remove the compressor nuts that fix the

 

 

 

 

 

 

 

 

Remove

 

 

 

 

 

 

compressor to the bottom board. (3 nuts)

 

 

 

 

 

(Outlet pipe)

 

 

 

 

 

 

12) Pull the compressor out toward you.

 

 

 

 

 

 

 

 

 

 

 

 

 

Note)

 

 

 

 

 

 

 

 

The compressor weighs 20 kg or more.

 

 

 

 

 

 

 

 

Two people should be required to handle it.

 

 

 

 

 

 

Remove (Suction pipe)

450

Compressor nut (3 nuts)

151

Page 152
Image 152
Toshiba HWS-802XWHM3-E, HWS-802XWHT6-E, HWS-802H-E, HWS-3001CSHM3-E(-UK), HWS-2101CSHM3-E(-UK) 151, Compressor nut 3 nuts