9. Anti Bacteria Setting

This setting regularly raises the hot water cylinder temperature to prevent bacteria from growing.

1 Press the HOT WATER button to start a hot water supply operation.

(Normal hot water supply operation)

(No anti bacteria setting is provided to heating and cooling.)

2 Pressing the ANTI BACTERIA button displays the symbol. (See display )

(The set temperature does not change) The hot water supply operation of 75°C starts.

The anti bacteria operation raises water temperature to 75°C with the heat pump and heater, and automatically ends after 30 minutes.

3 After that, an anti bacteria operation automatically starts at the

 

 

set time and cycle.

2,4

1

 

4 Pressing the ANTI BACTERIA button makes disappear, and the anti bacteria operation does not start.

<How to set anti bacteria temperature and holding time>

In FC_0A or 0B (See 2-2), the set temperature and holding time can be changed. FC_0A: Set temperature change range 70 to 80°C (75°C: default)

FC_0B: Holding time change range 0 to 60 minutes (30 minutes: default)

<How to set anti bacteria start time and cycle>

1 Press the ANTI BACTERIA button for 4 seconds or longer. (See display )

(Moves to the anti bacteria time setting mode)

"0C" in the Code No. field and the currently set and indication blink.

2

3

4

Press the TIME button to set a desired start time.

Pressing SET changes DATE (set time) 0C, and indication to be lit and the setting is confirmed.

Press the TEMP. button to change Code No. to "0d".

The "0d" and indication blink.

Press the TIME button to set a desired cycle.

Pressing SET changes DATE (set time) 0d, and indication to be lit and the setting is confirmed.

3

2, 4

51

5 Press the TEST button to exit the anti bacteria time setting mode.

115

Page 116
Image 116
Toshiba HWS-1501CSHM3-E(-UK), HWS-802XWHT6-E, HWS-802H-E, HWS-802XWHM3-E, HWS-3001CSHM3-E(-UK) Anti Bacteria Setting, 115