(2)-3. Sensor, Current, Compressor operation frequency, PMV openness indication

The values detected by controller, such as temperature sensor or current values, can be easily checked.

Legend)

D800 (Yellow)

D801 (Yellow) D802 (Yellow) D803 (Yellow) D804 (Yellow) D805 (Green)

---- Off ---- Light

Item setting

 

 

 

Temperature sensor (

 

 

)

 

 

 

 

 

TD

 

 

TE

 

 

TS

 

TO

 

 

 

 

TL

SW803

SW803

SW803

SW803

SW803

 

 

4

 

 

 

4

 

 

 

4

 

 

 

4

 

 

 

4

 

 

 

3

 

 

 

3

 

 

 

3

 

 

 

3

 

 

 

3

 

 

 

2

 

 

 

2

 

 

 

2

 

 

 

2

 

 

 

2

 

 

ON

1

 

 

ON

1

 

 

ON

1

 

 

ON

1

 

 

ON

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TH

 

 

TA

 

TC*

 

TCJ

 

 

 

 

SW803

SW803

SW803

SW803

 

 

 

 

Current

Compressor

PMV openness

 

 

(A)

operation

(pulse)

 

 

 

 

frequency

 

 

 

 

 

 

 

 

(r.p.s.)

 

 

 

 

SW803

SW803

SW803

 

 

4

 

 

 

4

 

 

 

4

 

 

 

3

 

 

 

3

 

 

 

3

 

 

 

2

 

 

 

2

 

 

 

2

 

 

ON

1

 

 

ON

1

 

 

ON

1

 

LED indication

 

 

4

 

 

 

 

 

3

 

 

 

 

2

ON

 

 

1

 

 

4

 

 

4

 

 

4

 

 

 

 

 

 

3

 

 

3

 

 

 

3

 

 

 

 

 

 

 

2

 

 

2

 

 

2

*See p122

ON

 

ON

 

1

ON

 

1

 

 

1

 

 

 

less than -25 -25 - -21 -20 - -16 -15 - -11 -10 - -6 -5 - -1

0 - 4

5-9

10-14

15-19

20-24

25-29

30-34

35-39

40-44

45-49

50-54

55-59

60-64

65-69

70-74

75-79

80-84

85-89

90-94

95-99

100-104

105-109

110-114

115-119

120 or higher

sensor failure, not connected

0-0.9

0-4

0-19

1-1.9

5-9

20-39

2-2.9

10-14

40-59

3-3.9

15-19

60-79

4-4.9

20-24

80-99

5-5.9

25-29

100-119

6-6.9

30-34

120-139

7-7.9

35-39

140-159

8-8.9

40-44

160-179

9-9.9

45-49

180-199

10-10.9

50-54

200-219

11-11.9

55-59

220-239

12-12.9

60-64

240-259

13-13.9

65-69

260-279

14-14.9

70-74

280-299

15-15.9

75-79

300-319

16-16.9

80-84

320-339

17-17.9

85-89

340-359

18-18.9

90-94

360-379

19-19.9

95-99

380-399

20-20.9

100-104

400-419

21-21.9

105-109

420-439

22-22.9

110-114

440-459

23-23.9

115-119

460-479

24-24.9

120-124

480-499

25-25.9

125-129

500

26-26.9

130-134

-

27-27.9

135-139

-

28-28.9

140-144

-

29-29.9

145-149

-

30-30.9

150-154

-

31 or higher

155 or higher

-

*TD, TL, and TH show errors below the ordinary temperature because they are sensors for high temperature.

*Current value for the outdoor unit only is shown.

124

Page 125
Image 125
Toshiba HWS-1402H-E 124, Item setting Temperature sensor, Current Compressor PMV openness Operation Pulse Frequency, 20-39