Toshiba HWS-1402XWHM3-E, HWS-802H-E F11 Error TWO sensor failure, F14 Error TTW sensor failure

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 88
Image 88
[F11] Error TWO sensor failure

[F11] Error TWO sensor failure

Start

TWO sensor

No

connector (CN205) is

 

 

connected

 

Yes

 

Correct TWO sensor connection

TWO sensor

No

 

Replace TWO sensor

characteristic is normal

 

(See characteristic table on page 101)

 

 

 

 

Yes

Replace water heat exchange control board

[F14] Error TTW sensor failure

Start

TTW sensor

No

connector (CN214) is

 

 

connected

 

Yes

 

Correct TTW sensor connection

TTW sensor

No

 

Replace TTW sensor

characteristic is normal

 

(See characteristic table on page 101)

 

 

 

 

Yes

Replace water heat exchange control board

[F17] Error TFI sensor failure

Start

 

 

 

 

 

 

 

 

 

TFI sensor

No

 

Correct TFI sensor

connector (CN213) is

 

 

connection

 

 

connected

 

 

 

 

 

Yes

 

 

 

TFI sensor

No

 

Replace TFI sensor

characteristic is normal

 

 

(See characteristic table on page 101)

Yes

 

 

 

 

 

 

 

 

Replace water heat exchange control board

 

 

 

 

 

 

 

87

Page 88
Image 88
Toshiba HWS-1402XWHM3-E F11 Error TWO sensor failure, F14 Error TTW sensor failure, F17 Error TFI sensor failure