Toshiba HWS-2101CSHM3-E(-UK) Exchange parts name, Work procedure, Remarks, Flow switch, Manometer

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 134
Image 134
Manometer

No.

Exchange parts name

Work procedure

Remarks

 

 

 

 

13

Flow switch

 

 

To replace a water circuit part, first close the water

 

 

 

 

 

 

supply source valve and the valve of water pipe

 

 

 

connected to the hydro unit.

 

 

 

 

 

1.How to remove

1)Perform the step 1-1 and step 5. 2)Remove the flow switch.

The flow switch connection uses an O ring for water seal. Be careful not to scratch the O ring; otherwise, water leakage may occur.

2.How to attach

1)Attach a new flow switch in the reverse order of the removal.

Note1)

 

As shown on the right,

 

place a flow sensor parallel to the water heat

Flow switch

exchanger inlet pipe so that the wire is place on

the right side from the front view.

Water heat inlet pipe

 

After the flow switch replacement repair, open the water supply source valve and water piping valve to pass water through the hydro unit, and check that the flow switch connection has no water leakage.

Flow switch

14 Manometer

To replace a water circuit part, first close the water supply source valve and the valve of water pipe connected to the hydro unit.

1.How to remove

1)Perform the step 1-1 and step 5 and 6. 2)Remove the manometer.

After the manometer replacement repair, open the water supply source valve and water piping valve to pass water through the hydro unit, and check that the manometer connection has no water leakage.

Manometer

133

Page 134
Image 134