Toshiba HWS-802XWHM3-E, HWS-802XWHT6-E, HWS-802H-E Overview, For operation, For display

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 122
Image 122
(1) Overview

16-3. Service support functions (LED indication, Switch operation method) The following settings are available with dip switches.

(1) Overview

Using 3 dip switches (SW802, SW803, SW804) and 2 push-button switches (SW800, SW801) can make settings available and confirm operations.

For operation

Part number

Specification

Operation details

 

 

 

SW800

Press button switch

This switch switches the indications of LED (D800 to D804) on the outdoor control board.

 

 

 

SW803

Dip switch

 

 

 

 

SW801

Press button switch

This switch enables users to perform a special operation for maintenance and inspection.

 

 

 

SW804

Dip switch

 

 

 

 

SW802

Dip switch

This switch performs initial settings. (See 8-4-6)

 

 

 

For display

Part number

Specification

Operation details

 

 

 

D502

Amber LED

Signal display (signals from the hydro unit) of communication between hydro unit and

 

outdoor unit (serial communication)

 

 

 

 

 

D503

Green LED

Signal display (signals from the outdoor unit) of communication between hydro unit and

 

outdoor unit (serial communication)

 

 

 

 

 

 

Yellow LED

Abnormality indication

D800 to D804

 

All OFF of SW803 or the lit status of any of D800 to D804 indicates that the outdoor

 

control unit detects an abnormality.

 

 

 

 

Setting SW803 to other than OFF shows details with LED indication.

 

 

 

 

Green LED

Energization indication

D805

 

This LED lights when the outdoor unit is energized.

 

 

During a special operation with the SW801 or SW804 operation, this LED blinks.

 

 

 

Note: All the LEDs have no color when off.

 

4

 

3

 

2

ON

1

SW804

SW801

D800

 

 

 

 

D801

 

 

 

 

 

D802

 

 

 

 

 

D803

 

 

 

 

 

D804

 

 

 

 

4

D805

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

2

 

 

 

ON

 

 

 

 

 

1

 

 

 

 

 

 

4

 

3

 

2

ON

1

Special operation switch (Operations for maintenance and inspection)

SW800

LED indication switching switch

SW803

 

 

D800 (Yellow LED)

 

D801

(Yellow LED)

Abnormality indication

D802

(Yellow LED)

D803

(Yellow LED)

and other indications

D804

(Yellow LED)

 

D805

(Green LED) ---Energization indication

D503

(Green LED) ---Serial signal (Outdoor to hydro)

D502

(Amber LED) ---Serial signal (Hydro to Outdoor)

SW802 ---Initial settings switching

121

Page 122
Image 122
Toshiba HWS-802XWHM3-E, HWS-802XWHT6-E Overview, For operation, For display, Note: All the LEDs have no color when off