Toshiba HWS-802XWHT6-E Exchange parts, Work procedure, Remarks, Fan motor lead Binding tie

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 140
Image 140
Fan motor lead

No.

Exchange parts

Work procedure

Remarks

name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Electric parts

2. Reactor

 

 

 

 

 

 

replacement

1)Perform the step 1-1.

 

 

 

 

 

 

 

Relay connector

 

 

 

 

 

 

 

 

 

 

2)Remove the relay connector connected to the

 

 

 

 

 

 

 

control board.

 

 

 

 

 

 

 

3)Cut the binding tie that binds the compressor leads

 

 

 

 

 

 

 

and relay connectors.

 

 

 

 

 

 

 

4)Remove the reactor.

 

 

 

 

 

 

 

(Truss B tight screw Ø4 × 6, 2 screws)

 

 

 

 

 

 

 

5)Attach a new reactor.

 

 

 

 

 

 

 

Note)

 

 

 

 

 

 

 

Be sure to bind the removed binding tie by using

 

 

 

 

 

 

 

 

 

Control board

 

 

 

 

the commercially available binding tie.

 

 

 

 

 

 

 

 

 

 

 

 

Make sure that the fan motor lead and the reactor

 

 

 

 

 

 

 

body do not contact each other.

 

 

Reactor body

 

Fan motor lead

Binding tie

(Compressor lead, Relay connector)