Toshiba HWS-1402H-E, HWS-802XWHT6-E, HWS-802H-E service manual Anti bacteria ANTI BACTERIA operation

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 45
Image 45
8) Anti bacteria (ANTI BACTERIA) operation

Item

 

 

 

Operation flow and applicable data, etc.

 

 

 

 

 

8-2.

8) Anti bacteria (ANTI BACTERIA) operation

Operation

An anti bacteria operation regularly performs a Hot water supply operation with the set temperature TSC_H = 75°C (can

Mode and

be set with FC_0A).

Control Method

 

 

 

 

 

 

1) How to operate

 

• Pressing the [HOT WATER] button and then the remote controller [ANTI BACTERIA] button changes the setting to

 

 

TSC_H = 75°C at the set cycle and time (both can be set with the remote controller FC) to start ANTI BACTERIA

 

 

operation.

 

The first auti bacteria operation starts when press the [ANTI BACTERIA] button and starting time come.

 

• When the set temperature 75°C is reached after the ANTI BACTERIA operation started, the set temperature remains

 

 

another 30 minutes (can be set with FC_0B).

 

The priority zone determined by the outside temperature selects an operation, Hot water heat pump or hot water

 

 

supply heater.

 

• The hot water heat pump operation, when selected, ignores the hot water supply start condition (TTW < 38°C) and

 

 

forcibly performs a hot water operation.

 

During ANTI BACTERIA operation (Forcible hot water operation at 75°C), the hot water set temperature display is

 

 

not changed. If it is changed from the remote controller, the normal hot water set temperature will be changed.

 

 

 

 

 

 

 

HOT WATER button set to "ON"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANTI BACTERIA button set to "ON"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anti bacteria start time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75°C hot water supply operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75°C hot water supply operation for 30 minutes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Usual hot water supply operation

 

 

 

 

(Set temperature: 40°C to 75°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual background Caution

During a 75°C hot water supply operation with ANTI BACTERIA, the remote controller does not display 75°C.

Be careful not to burn yourself; Output water may be hotter than that displayed on the remote controller.

Related FC

FC No.

Setting item

Default

Setting available range

 

 

 

 

0A

Anti bacteria set temperature

75°C

70-80°C

 

 

 

 

0B

Anti bacteria holding time

30 mins

0 - 60 mins

 

 

 

 

Remote control

Anti bacteria start time

22:00

0:00-22:00

OC

 

 

 

 

 

 

 

Remote control

Anti bacteria operation cycle

7 days

Every day to 10 days

OD

 

 

 

 

 

 

 

44

Page 45
Image 45
Toshiba HWS-1402H-E, HWS-802XWHT6-E, HWS-802H-E, HWS-802XWHM3-E, HWS-3001CSHM3-E(-UK) Anti bacteria ANTI BACTERIA operation