Toshiba HWS-2101CSHM3-E(-UK) Item, Operation flow and applicable data, etc, Heating side

Models: HWS-1402XWHT9-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1501CSHM3-E(-UK) HWS-1402H-E HWS-2101CSHM3-E(-UK) HWS-3001CSHM3-E(-UK) HWS-802XWHM3-E HWS-802H-E HWS-802XWHT6-E

1 168
Download 168 pages 43.83 Kb
Page 44
Image 44
HOT WATER button set to "ON"

Item

Operation flow and applicable data, etc.

 

 

8-2.

7) Hot water boost operation

Operation

A hot water boost operation boils water quickly to the set temperature TSC_H = 75°C (FC_09).

Mode and

 

Control Method

1) How to operate

When pressing the [HOT WATER BOOST] button after pressing the remote controller [HOT WATER] button, a heat pump operation in progress in the heating side switches to in the hot water side, and continues the operation regardless of the hot water supply start condition, TTW < 38°C. In addition, the hot water cylinder is immediately energized to start a Hot water supply operation under TSC_H = 75°C.

A hot water boost operation returns to the usual operation after 60 minutes.

The remote controller display during a hot water boost operation is the same as the set temperature display of a usual Hot water supply operation.

The usual set temperature change is used for changing the set temperature during a hot water boost operation. Change the BOOST set temperature with FC_09, if necessary.

HOT WATER button set to "ON"

HOT WATER BOOST button set to "ON"

 

 

 

Current heat pump

Heating side

 

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

Switches to Hot water

 

 

 

 

 

Hot water

 

 

 

 

 

 

 

 

 

supply operation

 

 

 

 

 

supply side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75°C Hot water operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 minutes passed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Usual operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Related FC

 

 

 

 

 

 

 

 

 

 

 

 

 

FC No.

Setting item

 

Default

Setting available range

 

 

 

 

 

 

 

09

HOT WATER BOOST set temperature

 

75°C

40-80°C

 

 

 

 

 

 

 

08

HOT WATER BOOST operation time

 

60 mins

30-180 mins

 

 

 

 

 

 

 

 

 

Every 10 mins

 

 

 

 

 

 

 

 

 

 