6-8 Agilent E5250A User’s Guide, Edition 9
Programming the E5250A
Creating a Control Program
Defining Channel Configuration Mode
Following commands are used to set the Channel Configuration mode. For details,
refer to “Channel List and Channel Configuration” on page 5-6.
Example: 100 OUTPUT @Hp5250;":ROUT:FUNC NCON"
110 ! Sets E5250A to Normal channel configuration mode.
Defining Connection Rule
Following commands are used to set the Connection Rule. For details, refer to
“Connection Rule” on page 5-9.
Example: 100 OUTPUT @Hp5250;":ROUT:CONN:RULE ALL,FREE"
110 ! Sets all cards to Free Connection rule.
Command Description
:ROUT:FUNC NCON Sets Normal Channel Configuration mode.
:ROUT:FUNC ACON Sets Auto Channel Configuration mode.
Command Description
:ROUT:CONN:RULE card_no,FREE Sets Free Connection rule.
:ROUT:CONN:RULE card_no,SROU Sets Single Connection rule.