Error Messages

 

E5250A Specific Error Messages

 

 

Error

Error Message and Description

Number

 

 

 

3013

Cannot connect multiple channels in SROUTe mode

 

Incorrect channel list for Single connection rule. For Single

 

connection rule, an input port cannot be connected to multiple output

 

ports, and an output port cannot be connected to multiple input ports.

 

Change channel list or change connection rule to Free.

 

 

3014

Cannot directly specify Bias Port channel

 

Incorrect channel number when Bias Mode ON is specified in the

 

channel list. Cannot directly specify the channel number for the Bias

 

Port.

 

 

3015

Bad channel number combination on E5252A card

 

Wrong input port combination is specified in the channel list for the

 

E5252A card. For input ports, can specify only one of input port

 

numbers 5, 7, and 9, and only one of input port numbers 6, 8, and 10.

 

For example, channel list cannot specify input ports 5 and 7.

 

 

3016

Config error. Re-install E5255A.

 

May be problem with the E5255A installation. Re-install the

 

E5255A.

 

 

3017

Too many relays closed. Max 200.

 

Too many physical relays have been closed. To close new relays,

 

must open some relays. Maximum 200 relays can be closed.

 

 

3018

Can't change to ACONfig mode. Check card config.

 

The present card configuration of the E5250A does not allow the

 

Auto Config mode. Change the E5250A card configuration to allow

 

Auto configuration mode.

 

 

3019

Cannot use same port for Couple and Bias

 

Same input port number is specified to be Couple Port and Bias Port.

 

Couple Port and Bias Port cannot be the same port.

 

 

Agilent E5250A User’s Guide, Edition 9

11-13

Page 317
Image 317