Cisco Systems 7500 Series manual Dbus slots XX Inlet Hotpoint

Models: 7500 Series

1 303
Download 303 pages 5.48 Kb
Page 109
Image 109

Chapter 2 Preparing for Installation

Environmental Monitoring and Reporting Overview for the Cisco 7500 Series

0123456

Dbus slots: XX XXX

inlet

hotpoint

exhaust

RSP(3) 16C/60F

24C/71F 20C/68F

 

Shutdown temperature source is 'hotpoint' slot3 (requested slot2)

+12V measured at 11.84

+5V measured at 5.05 -12V measured at -11.84 +24V measured at 23.78 +2.5 reference is 2.46

PS1 +5V Current PS1 +12V Current PS1 -12V Current PS1 output is 296 W

measured at 42.35

A (capacity 200

A)

measured

at

6.86

A

(capacity

35

A)

measured

at

0.55

A

(capacity

3

A)

When the system power is on, the blower must be operational. If the system detects that the blower has failed or is failing, it will display a warning message on the console screen. The entire system will shut down when the voltage at the hotpoint sensor (center of the RSP) reaches a predetermined value.

In the following example, the system has detected an out-of-tolerance blower, which it interprets as a blower failure.

%ENVM-2-FAN: Blower has failed.

When the temperature reaches a critical level, the system will display the following message on the console screen and in the show environment command display when the system restarts:

Queued messages:

%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown

Cisco 7513 and Cisco 7513-MX Environmental show Command Examples

In the Cisco 7513 and Cisco 7513-MX, the show environment command display reports the current environmental status of the system. The report displays parameters that are out of the normal values. No parameters are displayed if the system status is normal. The example that follows shows the display for a system in which all monitored parameters are within normal status range.

Note The current monitor circuits of the 7513 power supply are only accurate at high power levels. They are there to prevent over-configuration and serve no purpose at low power levels. If the system is not operating above 70% power, the measurement results are not accurate. Above 70%, the measurements have the degree of accuracy needed to prevent the insertion of too many line cards into the system.

Following is sample output of the show env command:

Router# show env

Environmental Statistics

Environmental status as of Wed 5-10-1995 16:42:48

Data is 0 second(s) old, refresh in 60 second(s)

All Environmental Measurements are within specifications

All measured values are normal

 

 

Cisco 7500 Series Installation and Configuration Guide

 

 

 

 

 

 

OL-5008-03 B0

 

 

2-31

 

 

 

 

 

Page 109
Image 109
Cisco Systems 7500 Series manual Dbus slots XX Inlet Hotpoint