Cisco Systems 7500 Series manual Parameter Normal Critical Shutdown, Parameter Critical Normal

Models: 7500 Series

1 303
Download 303 pages 5.48 Kb
Page 103
Image 103

Chapter 2 Preparing for Installation

Environmental Monitoring and Reporting Overview for the Cisco 7500 Series

)

Table 2-2 Typical Processor-Monitored Temperature Thresholds (Cisco 7505)

Parameter

Warning

Normal

Warning

Critical

Shutdown

 

 

 

 

 

 

 

 

 

Inlet air

< 10°C

10–39°C

39–46°C

46–64°C

> 64°C

 

 

 

 

 

 

 

 

 

Airflow

< 10°C

10–70°C

70–77°C

77–88°C

> 88°C

 

 

 

 

 

 

 

 

 

Table 2-3

Typical Power Supply-Monitored Voltage Thresholds (Cisco 7505)

 

 

 

 

 

 

 

 

 

 

Parameter

 

Critical

 

Normal

 

 

Critical

 

 

 

 

 

 

 

 

 

+5VDC

 

< 4.74

 

4.74–5.26

 

> 5.26

 

 

 

 

 

 

 

 

 

+12VDC

 

< 10.20

 

10.20 to 13.8

 

> 13.80

 

 

 

 

 

 

 

 

 

–12VDC

 

< –10.20

 

–10.20 to –13.80

 

> –13.80

 

 

 

 

 

 

 

 

 

+24VDC

 

< 20.00

 

20.00 to 28.00

 

> 28.00

 

 

 

 

 

 

 

 

 

 

Cisco 7507 and Cisco 7507-MX Temperature and Voltage Thresholds

Table 2-4lists temperature thresholds for the three processor-monitored levels. (The system displays all temperatures in Celsius only.) Table 2-5lists the DC power thresholds for the Normal and Critical power supply-monitored levels.

Table 2-4

Typical Processor-Monitored Temperature Thresholds (Cisco 7507 and Cisco 7507-MX)

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Normal

 

High Warning

High Critical

 

Shutdown

 

 

 

 

 

 

 

 

 

 

 

Inlet

 

10–40°C

 

44°C

 

50°C

 

 

 

 

 

 

 

 

 

 

 

 

 

Hotpoint

 

10–40°C

 

54°C

 

60°C

 

 

 

 

 

 

 

 

 

 

 

 

 

Exhaust

 

10–40°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processors

 

 

 

 

 

70°C

 

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

 

75°C

 

 

 

 

 

 

 

 

 

 

 

Restart

 

40°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2-5

Typical Power Supply-Monitored DC-Voltage Thresholds (Cisco 7507 and Cisco

 

7507-MX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Normal

Low Critical

Low Warning

High Warning

 

High Critical

 

 

 

 

 

 

 

 

 

 

+5VDC

4.74 to 5.26

4.61

 

4.94

 

5.46

 

 

5.70

 

 

 

 

 

 

 

 

 

 

+12VDC

10.20 to 13.8

10.90

 

11.61

 

12.82

 

 

13.38

 

 

 

 

 

 

 

 

–12VDC

–10.20 to –13.80

–10.15

–10.76

 

–13.25

 

–13.86

 

 

 

 

 

 

 

 

 

 

+24VDC

20.00 to 28.00

20.38

 

21.51

 

26.42

 

 

27.65

 

 

 

 

 

 

 

 

 

 

 

Cisco 7513, Cisco 7513-MX, and Cisco 7576 Temperature and Voltage Thresholds

Table 2-6lists temperature thresholds for the three processor-monitored levels. (The system displays all temperatures in Celsius only.) Table 2-7lists the DC power thresholds for the Normal and Critical power supply-monitored levels.

 

 

Cisco 7500 Series Installation and Configuration Guide

 

 

 

 

 

 

OL-5008-03 B0

 

 

2-25

 

 

 

 

 

Page 103
Image 103
Cisco Systems 7500 Series manual Parameter Normal Critical Shutdown, Parameter Critical Normal