Cisco Systems 7500 Series manual Removing and Replacing the Cisco 7505 Fan Tray

Models: 7500 Series

1 303
Download 303 pages 5.48 Kb
Page 187
Image 187

Chapter 5 Maintaining Your Cisco 7505 Router

Maintenance Procedures for the Cisco 7505

Removing and Replacing the Cisco 7505 Fan Tray

The fans on the fan tray provide cooling air to the internal system components. If the system detects that a fan has failed, it will display a 2-minute warning and then shut down the system until all of the fans are operational.

Note You cannot replace individual fans; if a fan fails, you must replace the entire fan tray assembly.

Figure 5-2 Replacing the Cisco 7505 Fan Tray

Removing/replacing

fan tray

H9726

When you view the chassis from the noninterface processor end, the fan tray is on the far right. See Figure 5-2.

A cutout in the front of the tray provides a handle for pulling the tray out of the chassis. An M4 Phillips screw anchors a tab on the bottom edge of the tray to the interior chassis frame, just below the right power supply ear.

When the fan tray is fully inserted in the chassis, an edge connector on the fan control board slides into the backplane electrical connector. The bottom of the tray is a metal runner that guides the tray along a metal track on the chassis floor. (See Figure 5-3.) Also, a bracket on the chassis ceiling helps guide the tray into the chassis.

Cisco 7500 Series Installation and Configuration Guide

 

OL-5008-03 B0

5-5

 

 

 

Page 187
Image 187
Cisco Systems 7500 Series manual Removing and Replacing the Cisco 7505 Fan Tray