Chapter 2 Preparing for Installation
Environmental Monitoring and Reporting Overview for the Cisco 7500 Series
+24 volts measured at 23.70(V) |
| |||
Airflow | temperature | measured | at 35(C) | |
Inlet | temperature | measured | at | 26(C) |
When the system power is on, all six fans in the fan array must be operational. If the system detects a failed or failing fan, it will display a warning message on the console screen. If the condition is not corrected within 2 minutes, the entire system will shut down to avoid an overtemperature condition and possible damage.
The system uses a Hall Effect signal to monitor the six fans in the array. The current to the fans and the magnetic field generated by the fans’ rotation generate a voltage, which the system monitors to determine if all of the fans are operating. If the monitored voltage signal drops below a specified value, the system assumes a fan failure and initiates a system shutdown.
In the following example, the system has detected an
If the system does shut down because of a fan failure, the system will display the following message on the console screen and in the environment display and in the show environment command display when the system restarts:
Queued messages:
Cisco 7507 and Cisco
In the Cisco 7507 and Cisco
Router# show env
All measured values are normal
If the environmental status is not normal, the system reports the
In the Cisco 7507 and Cisco
Following is sample output of the show env last command:
Router# show env last
RSP(2) Inlet | previously measured at 27C/80F | |
RSP(2) Hotpoint | previously measured at 38C/100F | |
RSP(2) Exhaust | previously measured at 31C/87F | |
+12 | Voltage | previously measured at 12.17 |
+5 Voltage | previously measured at 5.19 | |
Voltage | previously measured at | |
+24 | Voltage | previously measured at 23.40 |
In the Cisco 7507 and Cisco
|
| Cisco 7500 Series Installation and Configuration Guide |
|
| |
|
|
| |||
|
|
|
|
| |
|
|
|
|