Chapter 1 Cisco 7500 Series Product Overview

Fan Tray and Blower Assembly Overview

Cisco 7505 Fan Tray Assembly

The Cisco 7505 uses a fan tray assembly (see Figure 1-31) consisting of six fans that supply cooling air to the chassis interior. The assembly is accessible from behind the chassis front panel.

Figure 1-31 Fan Tray Assembly (Cisco 7505)

H9714

All six fans should be operating whenever system power is on. The system automatically shuts down if any one or more of the fans is operating outside the specified range. A variable speed feature allows the fans to operate at a slower speed when the internal chassis temperature is within the normal operating range, and at a higher speed if the internal temperature exceeds a specified temperature. (A spare fan tray ships as Product Number MAS/5-FAN=.) For fan tray maintenance information, see the “Removing and Replacing the Cisco 7505 Fan Tray” section on page 5-5.

Cisco 7507 and Cisco 7507-MX Blower Assembly

The Cisco 7507 and Cisco 7507-MX uses a blower assembly (see Figure 1-32) that supplies cooling air to the chassis interior. (A spare blower assembly ships as Product Number MAS-7KFAN=.) For blower assembly maintenance information, see the “Removing and Replacing the Cisco 7507 and Cisco 7507-MX Blower Assembly” section on page 6-15.

 

Cisco 7500 Series Installation and Configuration Guide

1-52

OL-5008-03 B0

Page 74
Image 74
Cisco Systems 7500 Series manual Cisco 7505 Fan Tray Assembly, Cisco 7507 and Cisco 7507-MX Blower Assembly