Cisco Systems manual RSP4 and RSP8 LEDs-Cisco 7500 Series

Models: 7500 Series

1 303
Download 303 pages 5.48 Kb
Page 260
Image 260

Chapter 8 Troubleshooting a Cisco 7500 Series Router

Using Cisco 7500 Series System LEDs

R E V I E W D R A F T — C I S CO CO N F I D E N T I A L

Caution The reset switch resets the RSP2 and the entire system. To prevent system errors and problems, use it only at the direction of your service representative.

Note The function of the master/slave switch, not available with the first release of the RSP2, allows you to designate which RSP2 acts as the system master and which as the slave. This functionality is only relevant for systems using two RSP2 processor modules in slot 6 and slot 7. RSP2s as spares are shipped as system masters by default. If two RSP2s are installed, one must be the master and one must be the slave, regardless of the slot in which they are installed (slot 2 and slot 3 in the Cisco 7507 and Cisco 7507-MX; slot 6 or slot 7 in the Cisco 7513 and Cisco 7513-MX).

The Cisco 7576 does not support master/slave operation. Only one RSP is used per router; therefore, the RSP in slot 6 is automatically the system master for router A, and the RSP in slot 7 is automatically the system master for router B.

RSP4 and RSP8 LEDs—Cisco 7500 Series

Figure 8-7shows the LEDs on the RSP4 and RSP8 faceplate. The LEDs on the RSP4 and RSP8 indicate the system and RSP4 or RSP8 status and which Flash memory card slot is active. The CPU halt LED, which goes on only if the system detects a processor hardware failure, should remain off. A successful boot is indicated when the normal LED goes on; however, this does not necessarily mean that the system has reached normal operation. During normal operation, the CPU halt LED should be off, and the normal LED should be on, indicating that the RSP4 or RSP8 is receiving +5V. The slot 0 and slot 1 LEDs indicate which PC Card (Flash memory) card slot is in use, and each LED blinks when the card is accessed by the system. The master and slave LEDs provide a visual indication of whether the RSP4 is designated as a master or a slave device.

Note The Cisco 7576 does not support master/slave operation. Only one RSP is used per router, designated router A and router B within the chassis; therefore, the RSP in slot 6 is automatically the system master for router A, and the RSP in slot 7 is automatically the system master for router B.

Figure 8-7 RSP4 and RSP8 LEDs (Partial Front Panel, Horizontal View)

NORMAL

SLOT

0

MASTER

SLAVE/MASTER CPU

HALT

RESET

 

1

 

 

 

 

SLOT

 

SLAVE

 

 

 

H9725

Caution The reset switch (see Figure 8-7) resets the RSP4 or RSP8 and the entire system. To prevent system errors and problems, use it only at the direction of your Cisco-certified service representative.

 