Cisco Systems 7500 Series Cisco 7505 Environmental show Command Examples, Router# show env last

Models: 7500 Series

1 303
Download 303 pages 5.48 Kb
Page 105
Image 105

Chapter 2 Preparing for Installation

Environmental Monitoring and Reporting Overview for the Cisco 7500 Series

Cisco 7576 Environmental show Command Examples, page 2-35

Note For complete show command descriptions and instructions, refer to the related software command reference publication, which is available on the Documentation CD-ROM, or in print. For a listing of available documentation, see the “If You Need More Configuration Information” section on page 4-32.

Cisco 7505 Environmental show Command Examples

In the Cisco 7505, the show environment command display reports the current environmental status of the system. The report displays the date and time of the query, the refresh times, the overall system status, and any parameters that are out of the normal values. No parameters are displayed if the system status is normal. The example that follows shows the display for a system in which all monitored parameters are within normal status range:

Router# show env

Environmental Statistics

Environmental status as of Wed 5-10-1995 16:42:48

Data is 0 second(s) old, refresh in 60 second(s)

All Environmental Measurements are within specifications

If the environmental status is not normal, the system reports the worst-case status level in the last line of the display, instead of the status summary that is shown in the last line of the preceding example. In the Cisco 7505, the show environment last command retrieves and displays the NVRAM log of the reason for the last shutdown and the environmental status at that time. If no status is available, it displays the reason as unknown.

Router# show env last

Environmental Statistics

Environmental status as of Wed 5-10-1995 16:42:48

Data is 10 second(s) old, refresh in 50 second(s)

All Environmental Measurements are within specifications

LAST Environmental Statistics

Environmental status as of Wed 5-10-1995 12:22:43

Power Supply: 600W, OFF

No Intermittent Powerfails

+12 volts measured at 12.05(V)

+5 volts measured at 4.82(V) -12 volts measured at -12.00(V) +24 volts measured at 23.90(V)

Air-Flow

temperature

measured

at

32(C)

Inlet

temperature

measured

at

26(C)

In the Cisco 7505, the show environment table command displays the temperature and voltage thresholds for each monitored status level, which are the same as those listed in Table 2-2and Table 2-3. The current measured values are displayed with the unit of measure noted, (V) or (C), and each is listed below a column heading that indicates its current status level. Measurements that fall within the Normal range are displayed in the Normal column of the table, whereas measurements that have reached a critical level are shifted to the Critical column, and so on.

 

 

Cisco 7500 Series Installation and Configuration Guide

 

 

 

 

 

 

OL-5008-03 B0

 

 

2-27

 

 

 

 

 

Page 105
Image 105
Cisco Systems 7500 Series manual Cisco 7505 Environmental show Command Examples, Router# show env last