Chapter 7 Maintaining Your Cisco 7513, Cisco 7513-MX, and Cisco 7576 Router

Maintenance Procedures for the Cisco 7513, Cisco 7513-MX, and Cisco 7576

Figure 7-5 Location of the EEPROM Device on the Rear of the Card Cage (Cisco 7513 and Cisco 7513-MX)

Chassis interface board

Pin 1

H8818

EEPROM device

Figure 7-6

Chassis interface board B

Location of the EEPROM Devices on the Rear of the Card Cage (Cisco 7576)

EEPROM B

Chassis interface board A

15271

EEPROM A

EEPROM device

Pin 1

Step 5 Remove the old EEPROM devices from the old card cage. Note where pin 1 is and use it as a reference insertion point. Immediately install the old EEPROM devices on the EEPROM sockets on your new card cage. (See Figure 7-5for the Cisco 7513 and Cisco 7513-MX, and Figure 7-6for the Cisco 7576.)

Step 6 Install the blank EEPROM devices)(that you removed from your new card cage and marked with tape) on the EEPROM sockets on your old card cage; remove the small piece of tape from the blank EEPROM devices. Return the old card cage to Cisco Systems.

Step 7 Repeat Step 5 and Step 6 for the second EEPROM in the Cisco 7576.

This completes the procedure for exchanging the EEPROM devices, which is required only if you exchange your existing card cage assembly for a new one.

Cisco 7500 Series Installation and Configuration Guide

7-8

OL-5008-03 B0

 

 

Page 226
Image 226
Cisco Systems 7500 Series manual Eeprom B